Beam tests of lead tungstate crystal matrices and a silicon strip preshower detector for the CMS electromagnetic calorimeter

被引:23
作者
Auffray, E
Baillon, P
Barney, D
Bassompierre, G
Benhammou, Y
Blick, A
Bloch, P
Bonamy, P
Bourotte, J
Buiron, L
Cavallari, F
Chipaux, R
Cockerill, D
Dafinei, I
Davies, G
Depasse, P
Deiters, K
Diemoz, M
Dobrzynski, L
Donskov, S
El Mamouni, H
Ercoli, C
Faure, JL
Felcini, M
Gautheron, F
Geleoc, M
Givernaud, A
Gninenko, S
Godinovic, N
Graham, DJ
Guillaud, JP
Guschin, E
Haguenauer, M
Hillemanns, H
Hofer, H
Ille, B
Inyakin, A
Jaaskelainen, S
Katchanov, V
Kirn, T
Kloukinas, K
Korzhik, M
Lassila-Perini, K
Lebrun, P
Lecoq, P
Lecoeur, G
Lecomte, P
Leonardi, E
Locci, E
Loos, R
机构
[1] CERN, Geneva, Switzerland
[2] LAPP, Annecy, France
[3] IPN Lyon, IN2P3, CNRS, Villeurbanne, France
[4] Univ Lyon 1, F-69622 Villeurbanne, France
[5] Ecole Polytech, LPNHE, Palaiseau, France
[6] Univ Roma La Sapienza, Rome, Italy
[7] Rutherford Appleton Lab, Didcot OX11 0QX, Oxon, England
[8] Paul Scherrer Inst, Villigen, Switzerland
[9] Swiss Fed Inst Technol, ETH, Zurich, Switzerland
[10] INR, Moscow, Russia
[11] Tech Univ Split, Split, Croatia
[12] RWTH 1, Aachen, Germany
[13] Inst Nucl Problems, Minsk, BELARUS
[14] Brunel Univ, Uxbridge UB8 3PH, Middx, England
[15] Univ Bristol, Bristol, Avon, England
[16] IHEP, Protvino, Russia
[17] Saclay, Gif Sur Yvette, France
[18] Imperial Coll Sci Technol & Med, London, England
[19] Univ Minnesota, Minneapolis, MN USA
关键词
D O I
10.1016/S0168-9002(98)00464-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Further tests of lead tungstate crystal matrices made in high-energy electron beams in 1996, using new crystals, new APDs and an improved test setup confirm that an energy resolution of better than 0.6% at 100 GeV can be obtained when the longitudinal uniformity of the struck crystal is adequate. Light loss measurements under low dose irradiation are reported. It is shown that there is no loss of energy resolution after irradiation and it is demonstrated that the calibration change due to light loss can be tracked with a precision monitoring system. Successful tests with a preshower device, equipped with a silicon strip detector readout. are also described. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:223 / 237
页数:15
相关论文
共 9 条
[1]   Studies of lead tungstate crystal matrices in high energy beams for the CMS electromagnetic calorimeter at the LHC [J].
Alexeev, G ;
Auffray, E ;
Baillon, P ;
Barney, D ;
Bassompierre, G ;
Bateman, E ;
Bell, KW ;
Benhammou, Y ;
Bloch, P ;
Bomestar, D ;
Borgia, B ;
Bourotte, J ;
Burge, S ;
Cameron, W ;
Chipaux, R ;
Cockerill, D ;
Connolly, J ;
Dafinei, I ;
Denes, P ;
Depasse, P ;
Deiters, K ;
Dobrzynski, L ;
ElMamouni, H ;
Faure, JL ;
Felcini, M ;
Finger, M ;
Flugel, T ;
Gautheron, F ;
Givernaud, A ;
Gninenko, S ;
Godinovic, N ;
Graham, DJ ;
Guillaud, JP ;
Guschin, E ;
Haguenauer, M ;
Hillemanns, H ;
Hofer, H ;
Ille, B ;
Jaaskelainen, S ;
Katchanov, V ;
Kennedy, B ;
Kirn, T ;
Korzhik, M ;
LassilaPerini, K ;
Lebeau, M ;
Lebrun, P ;
Lecoq, P ;
Lecoeur, G ;
Lecomte, P ;
Leonardi, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 385 (03) :425-434
[2]  
ANNENKOV A, UNPUB RAD MEASUREMEN
[3]  
ASPELL P, 1993, NUCL INSTRUM METH A, V344, P173
[4]  
*CERN PROGR LIB, Q123 CERN PROGR LIB
[5]  
*CMS, 1994, 9438 CERNLHCC CMS
[6]  
GRAHAM D, 96002 CMS
[7]   Results from tests on matrices of lead tungstate crystals using high energy beams [J].
Peigneux, JP ;
Schneegans, M ;
Bateman, E ;
Burge, S ;
Cockerill, D ;
Connolly, J ;
Smith, B ;
Stephenson, R ;
Auffray, E ;
Barney, D ;
Dafinei, I ;
Lecoq, P ;
Virdee, TS ;
Faure, JL ;
Givernaud, A ;
Locci, E ;
Verrecchia, P ;
Barney, J ;
Cameron, W ;
Clark, D ;
Miller, D ;
Seez, C ;
Williams, M ;
Rusack, R ;
Bourotte, J ;
Haguenauer, M ;
Korzhik, M ;
Alexeev, G ;
Katchanov, V ;
Oukhanov, M ;
Shagin, P ;
Singovsky, A ;
Denes, P ;
Fluegel, T ;
Renker, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (03) :410-426
[8]   ON QUALITY REQUIREMENTS TO THE BARIUM FLUORIDE-CRYSTALS [J].
ZHU, RY .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 340 (03) :442-457
[9]  
ZHU RY, 1996, 6 INT C CAL HEP FRAS, P577