Evaluation of a Nanoemulsion-Based Formulation for Respiratory Delivery of Budesonide by Nebulizers

被引:69
作者
Amani, Amir [1 ,2 ]
York, Peter [1 ]
Chrystyn, Henry [3 ]
Clark, Brian J. [1 ]
机构
[1] Univ Bradford, Sch Pharm, Inst Pharmaceut Innovat, Bradford BD7 1DP, W Yorkshire, England
[2] Univ Tehran Med Sci, Sch Adv Med Nanotechnol, Dept Med Nanotechnol, Tehran 1417614411, Iran
[3] Univ Huddersfield, Sch Appl Sci, Huddersfield HD1 3DH, W Yorkshire, England
关键词
budesonide; in vitro characterisation; microemulsion; nanoemulsion; nebulizer; suspension; SURFACTANT MICROEMULSIONS; HYDROFLUOROCARBON; 134A; PARTICLE-SIZE;
D O I
10.1208/s12249-010-9486-9
中图分类号
R9 [药学];
学科分类号
100702 [药剂学];
摘要
The aim of this work was to evaluate the in vitro performance of a nebulized nanoemulsion formulation which had been optimised previously. To do so, a transparent nanoemulsion preparation containing 1.5 mg/ml of budesonide was prepared and diluted to achieve concentrations of 250 and 500 mu g/ml budesonide. The in vitro characteristics of the diluted nanoemulsions were then compared with the commercially available suspension of budesonide (Pulmicort Respules (R)) when nebulized using a jet and a vibrating mesh nebulizer. A smaller MMAD with improved aerosol output was observed in the nanoemulsion preparations compared with the corresponding suspension formulations indicating an improved in vitro performance for the nanoemulsion-based preparations.
引用
收藏
页码:1147 / 1151
页数:5
相关论文
共 23 条
[1]
Aerodynamic Characteristics of Nebulized Terbutaline Sulphate Using the Next Generation Impactor (NGI) and CEN Method [J].
Abdelrahim, Mohamed E. ;
Chrystyn, Henry .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2009, 22 (01) :19-28
[2]
Almeziny M, 2007, J PHARM PHARMACOL, V59, pA28
[3]
AMANI A, 2008, THESIS U BRADFORD
[4]
Determination of factors controlling the particle size in nanoemulsions using Artificial Neural Networks [J].
Amani, Amir ;
York, Peter ;
Chrystyn, Henry ;
Clark, Brian J. ;
Do, Duong Q. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 35 (1-2) :42-51
[5]
Evaluation of supercritical fluid engineered budesonide powder for respiratory delivery using nebulisers [J].
Amani, Amir ;
Chrystyn, Henry ;
Clark, Brian J. ;
Abdelrahim, Mohamed E. ;
York, Peter .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2009, 61 (12) :1625-1630
[6]
Bennett W.D., 1997, Ann. Occup. Hyg, V41. Supplement 1, P497
[7]
Berg EB, 2009, RESP CARE, V54, P1671
[8]
*CEN, 2001, RESP THER EQ 1
[9]
COURRIER H, 2003, STP PHARM PRATIQUES, V13, P22
[10]
Selecting and using nebuliser equipment [J].
Kendrick, AH ;
Smith, EC ;
Wilson, RSE .
THORAX, 1997, 52 :S92-S101