Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS

被引:82
作者
Castiñeira, MM [1 ]
Brandt, R [1 ]
von Bohlen, A [1 ]
Jakubowski, N [1 ]
机构
[1] ISAS, D-44013 Dortmund, Germany
关键词
D O I
10.1007/s002160100862
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inductively coupled plasma mass spectrometric (ICP-MS) procedure has been developed for the determination of trace elements in wine. The procedure consists in simple 1+1 dilution of the wine and semi-quantitative analysis (without external calibration) using In as internal standard. Thirty-one elements at concentrations ranging from 0.1 mg mL(-1) to 0.5 ng mL(-1) can be determined by ICP-MS analysis with and without digestion. It was investigated whether a matrix effect observed for EtOH in the wine matrix can be overcome by application of a micro-concentric nebulizer with a membrane desolvator (MCN 6000). The results obtained for the MCN 6000 are compared with those obtained by use of a conventional Meinhard nebulizer. It is shown that the observed matrix effect can only be compensated by use of an internal standard for the Meinhard nebulizer, but not for the MCN 6000. Results for ICP-MS are compared with those obtained by total reflection X-ray fluorescence spectrometry (TXRF).
引用
收藏
页码:553 / 558
页数:6
相关论文
共 19 条
[1]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[2]  
Baxter MJ, 1997, FOOD CHEM, V60, P443, DOI 10.1016/S0308-8146(96)00365-2
[3]  
Carvalho ML, 1996, X-RAY SPECTROM, V25, P29, DOI 10.1002/(SICI)1097-4539(199601)25:1<29::AID-XRS134>3.0.CO
[4]  
2-Z
[5]  
Greenough JD, 1996, CAN J APPL SPECTROSC, V41, P76
[6]   Multivariate data visualisation methods based on multi-elemental analysis of wines and coffees using total reflection X-ray fluorescence analysis [J].
Haswell, SJ ;
Walmsley, AD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (02) :131-134
[7]   Analysis of wines by ICP-MS:: Is the pattern of the rare earth elements a reliable fingerprint for the provenance? [J].
Jakubowski, N ;
Brandt, R ;
Stuewer, D ;
Eschnauer, HR ;
Görtges, S .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05) :424-428
[8]  
Klockenkamper R, 1996, X-RAY SPECTROM, V25, P156, DOI 10.1002/(SICI)1097-4539(199607)25:4<156::AID-XRS154>3.3.CO
[9]  
2-V
[10]   DETERMINATION OF THE CRITICAL THICKNESS AND THE SENSITIVITY FOR THIN-FILM ANALYSIS BY TOTAL REFLECTION X-RAY-FLUORESCENCE SPECTROMETRY [J].
KLOCKENKAMPER, R ;
VONBOHLEN, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1989, 44 (05) :461-469