Dual-modality PET/CT scanning with negative oral contrast agent to avoid artifacts: Introduction and evaluation

被引:117
作者
Antoch, G
Kuehl, H
Kanja, J
Lauenstein, TC
Schneemann, H
Hauth, E
Jentzen, W
Beyer, T
Goehde, SC
Debatin, JF
机构
[1] Univ Hosp Essen, Dept Diagnost & Intervent Radiol, D-45122 Essen, Germany
[2] Univ Hosp Essen, Dept Nucl Med, D-45122 Essen, Germany
[3] Univ Hosp Essen, Dept Pharm, D-45122 Essen, Germany
关键词
dual-modality imaging; PET/CT;
D O I
10.1148/radiol.2303021287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors qualitatively and quantitatively assessed a solution containing 0.2% locust bean gum (LBG) and 2.5% mannitol (mannitol-LBG) dissolved in water to provide a negative oral contrast material in dual-modality positron emission tomography (PET)/computed tomography (CT) scanning. PET/CT was performed in 60 patients with cancer after oral administration of barium, water, or mannitol-LBG. Qualitative and quantitative analyses were conducted to determine bowel distention and a potential influence of the contrast agents on the PET data. Intestinal distention with mannitol-LBG proved superior to that with water or barium. Findings at both quantitative and qualitative analysis revealed apparently increased tracer uptake in the small bowel with barium in comparison to that with mannitol-LBG or water. Mannitol-LBG may, therefore, be used as a negative oral contrast agent at PET/CT scanning because it provides excellent bowel distention while avoiding contrast material-induced PET artifacts. (C) RSNA, 2004.
引用
收藏
页码:879 / 885
页数:7
相关论文
共 19 条
  • [1] Antoch G, 2002, J NUCL MED, V43, P1339
  • [2] Beyer T, 2000, J NUCL MED, V41, P1369
  • [3] CARNEY J, 2001, IEEE ANN M SAN DIEG
  • [4] Cohade C, 2003, J NUCL MED, V44, P412
  • [5] Application of oral contrast media in coregistered positron emission tomography-CT
    Dizendorf, EV
    Treyer, V
    von Schulthess, GK
    Hany, TF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) : 477 - 481
  • [6] Franquiz JM, 2002, J NUCL MED, V43, p217P
  • [7] HAWKINS RA, 1992, J NUCL MED, V33, P339
  • [8] Huang SC, 2000, NUCL MED BIOL, V27, P643
  • [9] PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV
    HUBBELL, JH
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11): : 1269 - 1290
  • [10] Attenuation correction for a combined 3D PET/CT scanner
    Kinahan, PE
    Townsend, DW
    Beyer, T
    Sashin, D
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 2046 - 2053