Numeric modeling of the cardiovascular system with a left ventricular assist device

被引:27
作者
Zhou, JH
Armstrong, GP
Medvedev, AL
Smith, WA
Golding, LAR
Thomas, JD
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
[2] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
D O I
10.1097/00002480-199901000-00019
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A numeric model consisting of a lump-parameter cardiovascular system (CVS) model and a model for the Cleveland Clinic Implantable Ventricular Assist System (IVAS), a nonpulsatile rotary pump designed to augment the failing left ventricle, are described in this paper. The purposes of this study were to 1) observe the hemodynamic interactions between CVS and IVAS under various physiologic and pathophysiologic conditions running at different speeds; and 2) allow testing and optimization of various IVAS control algorithms. An existing numeric model of CVS (24 coupled differential equations, representing all cardiac chambers and systemic and pulmonary vasculature) was modified to add the IVAS pump as an auxiliary chamber between the left ventricle and aorta with pressure-flow-speed characteristics derived from in vitro testing. Simulations were conducted for ventricles with normal and abnormal systolic and diastolic dysfunction at different exercise levels with the pump running at various speeds. Computer simulations show that 1) numeric modeling is useful for predicting hemodynamic response of CVS to IVAS in various circumstances; 2) IVAS results in normalization of cardiac output, especially in failing hearts, although with reduced pulse pressure; and 3) various control algorithms allowing adaptation of IVAS to physiologic demands of CVS could be developed based on the simulation study.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 15 条
[1]
Control of the artificial heart [J].
Allen, GS ;
Murray, KD ;
Olsen, DB .
ASAIO JOURNAL, 1996, 42 (06) :932-937
[2]
CAMMILLI L, 1993, PACING CLIN ELECTROP, V6, P488
[3]
EFFECTS OF MITRAL REGURGITATION ON PULMONARY VENOUS FLOW AND LEFT ATRIAL PRESSURE - AN INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC STUDY [J].
KLEIN, AL ;
STEWART, WJ ;
BARTLETT, J ;
COHEN, GI ;
KAHAN, F ;
PEARCE, G ;
HUSBANDS, K ;
BAILEY, AS ;
SALCEDO, EE ;
COSGROVE, DM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (06) :1345-1352
[4]
LEUNG D, IN PRESS LATENT LEFT
[5]
Does successful bridging with the implantable left ventricular assist device affect cardiac transplantation outcome? [J].
Massad, MG ;
McCarthy, PM ;
Smedira, NG ;
Cook, DJ ;
Ratliff, NB ;
Goormastic, M ;
Vargo, RL ;
Navia, J ;
Young, JB ;
Stewart, RW .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (05) :1275-1281
[6]
HEARTMATE IMPLANTABLE LEFT-VENTRICULAR ASSIST DEVICE - BRIDGE TO TRANSPLANTATION AND FUTURE APPLICATIONS [J].
MCCARTHY, PM .
ANNALS OF THORACIC SURGERY, 1995, 59 (02) :S46-S51
[7]
MCCARTHY PM, 1994, CIRCULATION, V90, P83
[8]
Numerical simulation of nonpulsatile left ventricular bypass [J].
Mitsui, N ;
Fukunaga, S ;
Koura, Y ;
Morita, S ;
Hotei, H ;
Sueshiro, M ;
Sueda, T ;
Matsuura, Y .
ARTIFICIAL ORGANS, 1996, 20 (06) :632-636
[9]
Left ventricular echocardiographic and histologic changes: Impact of chronic unloading by an implantable ventricular assist device [J].
Nakatani, S ;
McCarthy, PM ;
KottkeMarchant, K ;
Harasaki, H ;
James, KB ;
Savage, RM ;
Thomas, JD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (04) :894-901
[10]
Left ventricular diastolic filling with an implantable ventricular assist device: Beat to beat variability with overall improvement [J].
Nakatani, S ;
Thomas, JD ;
Vandervoort, PM ;
Zhou, JH ;
Greenberg, NL ;
Savage, RM ;
McCarthy, PM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (05) :1288-1294