Electromagnetic navigation during flexible bronchoscopy

被引:110
作者
Schwarz, Y
Mehta, AC
Ernst, A
Herth, F
Engel, A
Besser, D
Becker, HD
机构
[1] Sackler Fac Med, Inst Pulm & Allergy Dis, Tel Aviv Sourasky Med Ctr, Dept Pulm Med, IL-64239 Tel Aviv, Israel
[2] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[3] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
[4] Thoraxklin, Heidelberg, Germany
[5] Rambam Med Ctr, Haifa, Israel
[6] SuperDimens Ltd, Herzliyya, Israel
关键词
animal trial; biopsy; peripheral lung lesion; bronchoscopy; CT-guided; virtual bronchoscopy; electromagnetic navigation;
D O I
10.1159/000074210
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Flexible bronchoscopy is routinely utilized in the diagnosis and treatment of various lung diseases. Nondiagnostic bronchoscopy leads to more invasive interventions, such as transthoracic needle aspiration, mediastinoscopy or even thoracotomy. Electromagnetic navigation is a novel technology that facilitates approaching peripheral lung lesions, which are difficult to sample by conventional means. The navigation system involves creating an electromagnetic field around the chest and localizing an endoscopic tool using a microsensor overlaid upon previously acquired CT images. Objectives: To determine the practicality, accuracy and safety of real-time electromagnetic navigation, coupled with previously acquired 3D CT images, in locating artificially created peripheral lung lesions in a swine model. Methods: Peripheral lung lesions were created in four swine models by insertion of a metal tube (1 x 10 mm) via a transthoracic approach. An electromagnetic field was created by placing the animal on an electromagnetic location board. A position sensor incorporated into the distal tip of a dedicated tool was used to navigate to the various target lesions. Information gathered in real time during bronchoscopy was presented on a monitor simultaneously by displaying previously acquired CT images. Upon reaching the target lesion, biopsies were performed and the functionality and safety of the superDimension/ Bronchus System was observed and documented. Results: The registration accuracy expressed by the fiducial target registration error, expressing both the registration quality and the stability of fiducial ( registration) points, was 4.5 mm on average. No adverse effects, such as pneumothorax or internal bleeding, were encountered in any of the animals in this study. Conclusions: Real-time electromagnetic positioning technology coupled with previously acquired CT images is an accurate technology added to standard bronchoscopy to assist in reaching peripheral lung lesions and performing biopsies. Copyright c 2003 S. Karger AG, Basel.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 13 条
[1]  
*AG HEALTHC RES QU, 2001, HEALTHC COST UT PROJ
[2]   Diagnostic yield of fiberoptic bronchoscopy in evaluating solitary pulmonary nodules [J].
Baaklini, WA ;
Reinoso, MA ;
Gorin, AB ;
Sharafkanch, A ;
Manian, P .
CHEST, 2000, 117 (04) :1049-1054
[3]   TRANS-BRONCHIAL NEEDLE ASPIRATION IN THE PRACTICE OF BRONCHOSCOPY [J].
GAY, PC ;
BRUTINEL, WM .
MAYO CLINIC PROCEEDINGS, 1989, 64 (02) :158-162
[4]   CT-guided percutaneous core biopsies of pulmonary lesions -: Diagnostic accuracy, complications and therapeutic impact [J].
Hänninen, EL ;
Vogl, TJ ;
Ricke, J ;
Felix, R .
ACTA RADIOLOGICA, 2001, 42 (02) :151-155
[5]   Computed tomographic fluoroscopy-guided transthoracic needle biopsy for diagnosis of pulmonary nodules [J].
Hirose, T ;
Mori, K ;
Machida, S ;
Tominaga, K ;
Yokoi, K ;
Adachi, M .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2000, 30 (06) :259-262
[6]  
HOFFMANN H, 2000, DTSCH ARZTEBL, V97, pB907
[7]   DIAGNOSTIC-ACCURACY IN PERIPHERAL LUNG LESIONS - FACTORS PREDICTING SUCCESS WITH FLEXIBLE FIBEROPTIC BRONCHOSCOPY [J].
RADKE, JR ;
CONWAY, WA ;
EYLER, WR ;
KVALE, PA .
CHEST, 1979, 76 (02) :176-179
[8]   The value of transbronchial needle aspiration in the diagnosis of peripheral pulmonary lesions [J].
Reichenberger, F ;
Weber, J ;
Tamm, M ;
Bolliger, CT ;
Dalquen, P ;
Perruchoud, AP ;
Solèr, M .
CHEST, 1999, 116 (03) :704-708
[9]   Real-time bronchoscope tip localization enables three-dimensional CT image guidance for transbronchial needle aspiration in swine [J].
Solomon, SB ;
White, P ;
Acker, DE ;
Strandberg, J ;
Venbrux, AC .
CHEST, 1998, 114 (05) :1405-1410
[10]   SOLITARY PULMONARY NODULE [J].
STOLLER, JK ;
AHMAD, M ;
RICE, TW .
CLEVELAND CLINIC JOURNAL OF MEDICINE, 1988, 55 (01) :68-74