Hydrophobic interaction electrokinetic chromatography for the separation of polycyclic aromatic hydrocarbons using non-aqueous matrices

被引:14
作者
Koch, JT [1 ]
Beam, B [1 ]
Phillips, KS [1 ]
Wheeler, JF [1 ]
机构
[1] Furman Univ, Dept Chem, Greenville, SC 29613 USA
基金
美国国家科学基金会;
关键词
electrokinetic chromatography; hydrophobic interaction electrokinetic chromatography; non-aqueous capillary electrophoresis; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(01)00521-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Capillary electrophoresis methodology is developed to provide a rapid, inexpensive and robust technique for screening polycyclic aromatic hydrocarbons (PAHs) in water using additive complexation. A series of conventional RPLC ion-pairing agents are investigated in three different totally non-aqueous separation solvents, and the relative role of hydrophobic interaction versus electrostatic association is evaluated. Methanol is found to provide optimal selectivity when coupled with the tetrahexylammonium cation providing total analysis times of approximately 15 min for the analysis of thirteen 2-7-ring PAH pollutants. Solid-phase microextraction is demonstrated to be an effective sample preparation technique for extraction/preconcentration of PAHs from water into methanol run buffer prior to injection. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 36 条
[1]   SEPARATION OF VERY HYDROPHOBIC COMPOUNDS BY HYDROPHOBIC INTERACTION ELECTROKINETIC CHROMATOGRAPHY [J].
AHUJA, ES ;
FOLEY, JP .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :73-83
[2]   Analyte-additive interactions in nonaqueous capillary electrophoresis: a critical review [J].
Bowser, MT ;
Kranack, AR ;
Chen, DDY .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1998, 17 (07) :424-434
[3]  
Brown RS, 1996, J MOL RECOGNIT, V9, P515, DOI 10.1002/(SICI)1099-1352(199634/12)9:5/6<515::AID-JMR294>3.0.CO
[4]  
2-5
[5]   COMPARISON OF MICELLAR ELECTROKINETIC CHROMATOGRAPHY (MEKC) WITH CAPILLARY GAS-CHROMATOGRAPHY IN THE SEPARATION OF PHENOLS, ANILINES AND POLYNUCLEAR AROMATICS - POTENTIAL FIELD-SCREENING APPLICATIONS OF MEKC [J].
BRUMLEY, WC ;
JONES, WJ .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :163-173
[6]  
Copper Christine L., 1994, Analytical Chemistry, V66, P147, DOI 10.1021/ac00073a025
[7]  
DabekZlotorzynska E, 1996, J CAPILLARY ELECTROP, V3, P31
[8]   USE OF COMPLEXING AGENTS FOR SELECTIVE SEPARATION IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS - CHIRAL RESOLUTION VIA CYCLODEXTRINS INCORPORATED WITHIN POLYACRYLAMIDE-GEL COLUMNS [J].
GUTTMAN, A ;
PAULUS, A ;
COHEN, AS ;
GRINBERG, N ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01) :41-53
[9]   Selectivity enhancement in capillary electrophoresis using non-aqueous media [J].
Hansen, SH ;
Tjornelund, J ;
Bjornsdottir, I .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (04) :175-180
[10]  
LISTER AS, 1997, J HIGH RES CHROMATOG, V20, P523