Aqueous humor dynamics in mice

被引:135
作者
Aihara, M
Lindsey, JD
Weinreb, RN
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
关键词
D O I
10.1167/iovs.03-0504
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess aqueous humor dynamics in mouse eyes. METHODS. Aqueous humor dynamics of NIH Swiss White mouse were assessed with an injection and aspiration system, using fine glass microneedles. Intraocular pressure (IOP) was measured by a microneedle connected to a pressure transducer. Episcleral venous pressure (EVP) was measured by gradually lowering intracameral pressure until blood reflux into Schlemm's canal was observed. Outflow facility (C) was determined based on constant pressure perfusion measurements obtained at two different IOPs. Aqueous volume (V-a) was determined by direct measurement of aspirated aqueous humor. Aqueous humor production (F-a) was measured by the dilution method with rhodamine-dextran. Conventional and uveoscleral outflow (F-c and F-u, respectively), as well as the turnover rate of aqueous humor, were also calculated. RESULTS. IOP and EVP were 15.7 +/- 2.0 and 9.5 +/- 1.2 mm Hg, respectively (n = 20). F-a was 0.18 +/- 0.05 muL/min (mean +/- SD; n = 8). C was 0.0051 +/- 0.0006 muL/min per mm Hg (n = 8). Estimated F-c and F-u were 0.032 and 0.148 muL/min, respectively. F-c was 18% of F-a. F-u was 82% of F-a. V-a was 5.9 +/- 0.5 muL (n = 8). The calculated turnover rate of aqueous humor was 2.5%. CONCLUSIONS. The mouse eye has similar aqueous production and aqueous humor turnover rate as the human eye. The presence of both conventional and uveoscleral outflow suggests that the mouse is a useful model system for further investigations of the biology of aqueous dynamics.
引用
收藏
页码:5168 / 5173
页数:6
相关论文
共 28 条
[1]   Twenty-four-hour pattern of mouse intraocular pressure [J].
Aihara, M ;
Lindsey, JD ;
Weinreb, RN .
EXPERIMENTAL EYE RESEARCH, 2003, 77 (06) :681-686
[2]  
Aihara M, 2002, INVEST OPHTH VIS SCI, V43, P146
[3]   Uveoscleral outflow [J].
Alm, A .
EYE, 2000, 14 (3) :488-491
[4]   THE FACILITY OF AQUEOUS OUTFLOW - A COMPARISON OF TONOGRAPHY AND PERFUSION MEASUREMENTS INVIVO AND INVITRO [J].
BECKER, B ;
CONSTANT, MA .
ARCHIVES OF OPHTHALMOLOGY, 1956, 55 (03) :305-312
[5]  
BILL A, 1966, DOC OPHTHALMOL, V20, P157
[7]  
BRUBAKER RF, 1966, ARCH OPHTHALMOL-CHIC, V75, P693
[8]  
COLE DF, 1984, EYE, P39
[9]   AQUEOUS CHAMBER DRUG DISTRIBUTION VOLUME MEASUREMENT IN RABBITS [J].
CONRAD, JM ;
ROBINSON, JR .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1977, 66 (02) :219-224
[10]   Method for the noninvasive measurement of intraocular pressure in mice [J].
Danias, J ;
Kontiola, AI ;
Filippopoulos, T ;
Mittag, T .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (03) :1138-1141