Variation of anatomic valve area during ejection in patients with valvular aortic stenosis evaluated by two-dimensional echocardiographic planimetry: Comparison with traditional Doppler data

被引:35
作者
Arsenault, M [1 ]
Masani, N [1 ]
Magni, G [1 ]
Yao, JF [1 ]
Deras, L [1 ]
Pandian, N [1 ]
机构
[1] Tufts Univ, New England Med Ctr, NonInvas Cardiac Imaging Lab, Boston, MA 02111 USA
关键词
D O I
10.1016/S0735-1097(98)00460-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Flow variations can affect valve-area calculation in aortic stenosis and lead to inaccuracies in the evaluation of the stenosis. Knowing that transvalvular how varies normally within one beat, we designed this study to assess the response of the valve to intrabeat variation of flow during systole. Results were compared with flow derived measurements. Background. Technological improvements now allow us to evaluate aortic valve area directly by short axis planimetry, This offers the possibility to perform serial planimetries during one ejection phase and analyze the intrabeat dynamic behavior of the stenotic-aortic valve and compare these measurements with flow-derived measurements. Methods. Forty echocardiograms displaying different degrees of aortic stenosis were analyzed by frame-by frame planimetry of the valve area from onset of opening to complete closure. Maximal-mean area, opening and closing rates and ejection times were obtained and compared with Doppler-derived data. Results. Valve area varied during ejection. Stenotic valves opened and closed more slowly than normals and remained maximally open for a shorter period. Mean area by Doppler data corresponded more closely to maximal than to mean-planimetered area. Duration of flow was shorter than valve opening in severely stenotic valves, Discrepancies between Doppler-derived and two-dimensional (2D) measurements decreased in less stenotic valves. Conclusions. Our observations reveal striking differences between the dynamics of normal and stenotic valves. Surprisingly, Doppler-derived mean-valve area correlated better with maximal-anatomic area than with mean-anatomic area in patients with aortic stenosis. Discrepancies between duration of flow and valve opening could explain this phenomenon. (J Am Coll Cardiol 1998;32:1931-7) (C) 1998 by the American College of Cardiology.
引用
收藏
页码:1931 / 1937
页数:7
相关论文
共 31 条
[1]   HEMODYNAMIC EFFECTS OF EXERCISE IN ISOLATED VALCULAR AORTIC STENOSIS [J].
BACHE, RJ ;
WANG, Y ;
JORGENSEN, CR .
CIRCULATION, 1971, 44 (06) :1003-+
[2]  
BECKBERG G, 1975, AM J CARDIOL, V35, P778
[3]   EVALUATION OF AORTIC-STENOSIS BY CONTINUOUS WAVE DOPPLER ULTRASOUND [J].
BERGER, M ;
BERDOFF, RL ;
GALLERSTEIN, PE ;
GOLDBERG, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :150-156
[4]   FLOW DEPENDENCE OF MEASURES OF AORTIC-STENOSIS SEVERITY DURING EXERCISE [J].
BURWASH, IG ;
PEARLMAN, AS ;
KRAFT, CD ;
MIYAKEHULL, C ;
HEALY, NL ;
OTTO, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) :1342-1350
[5]   ECHOCARDIOGRAPHIC VOLUME FLOW AND STENOSIS SEVERITY MEASURES WITH CHANGING FLOW-RATE IN AORTIC-STENOSIS [J].
BURWASH, IG ;
FORBES, AD ;
SADAHIRO, M ;
VERRIER, ED ;
PEARLMAN, AS ;
THOMAS, R ;
KRAFT, C ;
OTTO, CM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 265 (05) :H1734-H1743
[6]   ADVANCES IN THE HEMODYNAMIC ASSESSMENT OF STENOTIC CARDIAC VALVES [J].
CARABELLO, BA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :912-919
[7]   HEMODYNAMIC DETERMINANTS OF PROGNOSIS OF AORTIC-VALVE REPLACEMENT IN CRITICAL AORTIC-STENOSIS AND ADVANCED CONGESTIVE HEART-FAILURE [J].
CARABELLO, BA ;
GREEN, LH ;
GROSSMAN, W ;
COHN, LH ;
KOSTER, JK ;
COLLINS, JJ .
CIRCULATION, 1980, 62 (01) :42-48
[8]   Value of multiplane transesophageal echocardiography in determining aortic valve area in aortic stenosis [J].
Cormier, B ;
Iung, B ;
Porte, JM ;
Barbant, S ;
Vahanian, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (10) :882-&
[9]   THEORETICAL AND PRACTICAL DIFFERENCES BETWEEN THE GORLIN FORMULA AND THE CONTINUITY EQUATION FOR CALCULATING AORTIC AND MITRAL-VALVE AREAS [J].
DUMESNIL, JG ;
YOGANATHAN, AP .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (15) :1268-1272
[10]   REGULATION OF THE AORTIC-VALVE OPENING - IN-VIVO DYNAMIC MEASUREMENT OF AORTIC-VALVE ORIFICE AREA [J].
HIGASHIDATE, M ;
TAMIYA, K ;
BEPPU, T ;
IMAI, Y .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (02) :496-503