Energy signatures for assessing the energy performance of chillers

被引:39
作者
Yu, FW [1 ]
Chan, KT [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
building cooling load; chiller energy performance; energy signatures;
D O I
10.1016/j.enbuild.2004.10.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates how energy signatures can be used as an alternative to an energy use intensity (describing the annual electricity consumption of chillers in kWh per unit floor area of a building in m(2)) to assess the energy performance of chillers with various design options and operating strategies. An energy signature is a best-fit straight line relating chiller power to a climatic index when chillers operate for a building cooling load profile. Sixteen combinations of four design options and four operating strategies for chillers serving a hypothetical hotel are studied by simulation. For each combination, an energy signature for the chillers is determined. The slope and intercept of the energy signature can be used to accurately predict the annual electricity consumption of the chillers and to evaluate the extent to which this consumption can drop when chiller efficiency is improved. It is desirable to develop reference energy signatures in relation to different characteristics of building cooling load as a yardstick for the minimum requirement of chiller performance. With this yardstick, the effectiveness of energy efficient measures in the operation of chillers Could be identified. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:739 / 746
页数:8
相关论文
共 18 条
[1]  
Chan K.T., 2002, BUILD SERV ENG RES T, V23, P29
[2]   Optimum setpoint of condensing temperature for air-cooled chillers [J].
Chan, KT ;
Yu, FW .
HVAC&R RESEARCH, 2004, 10 (02) :113-127
[3]   Applying condensing-temperature control in air-cooled reciprocating water chillers for energy efficiency [J].
Chan, KT ;
Yu, FW .
APPLIED ENERGY, 2002, 72 (3-4) :565-581
[4]  
Day AR, 2003, BUILD SERV ENG RES T, V24, P221
[5]   A study of energy performance of hotel buildings in Hong Kong [J].
Deng, SM ;
Burnett, J .
ENERGY AND BUILDINGS, 2000, 31 (01) :7-12
[6]   Heat-load modelling for large systems [J].
Heller, AJ .
APPLIED ENERGY, 2002, 72 (01) :371-387
[7]   Electricity use characteristics of purpose-built office buildings in subtropical climates [J].
Lam, JC ;
Chan, RYC ;
Tsang, CL ;
Li, DHW .
ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (06) :829-844
[8]   Energy analysis of commercial buildings in subtropical climates [J].
Lam, JC .
BUILDING AND ENVIRONMENT, 2000, 35 (01) :19-26
[9]  
Levermore G., 1995, BUILDING SERVICES EN, V16, P47
[10]   ENERGY SIGNATURE MODELS FOR COMMERCIAL BUILDINGS - TEST WITH MEASURED DATA AND INTERPRETATION [J].
RABL, A ;
RIALHE, A .
ENERGY AND BUILDINGS, 1992, 19 (02) :143-154