A comparison between PTFE and denatured homologous vein grafts for haemodialysis access: a prospective randomised multicentre trial

被引:44
作者
Bosman, PJ [1 ]
Blankestijn, PJ [1 ]
van der Graaf, Y [1 ]
Heintjes, RJ [1 ]
Koomans, HA [1 ]
Eikelboom, BC [1 ]
机构
[1] Univ Utrecht Hosp, Dept Vasc Surg, Utrecht, Netherlands
关键词
haemodialysis; vascular access; polytetrafluoroethylene; homologous vein; randomised trial; complications;
D O I
10.1016/S1078-5884(98)80153-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To compare patency and complication rates of polytetrafluoroethylene (PTFE) grafts and denatured homologous vein (DHV) grafts for long-term haemodialysis. Design: A prospective randomised multicentre trial. Materials: One hundred and thirty-one patients were enrolled between September 1994 and April 1997. Sixty-three DHV grafts and 68 PTFE grafts were implanted in 60 males and 71 females. Complications and interventions were monitored. Patency rates, complication rates, and intervention rates of PTFE and DHV were compared. Results: The mean follow-up was 313 days for DHV (range 1-771) and 339 (3-909) days for PTFE. The total follow-up was 54.1 patient-years for DHV and 63.1 for PTFE. The 1-year primary patency rates were 30% and 40% for DHV and PTFE respectively. Secondary patency rate was 63% for both DHV and PTFE. Most frequent complication was thrombosis. A total of 75 thrombotic events (1.39 per patient-year) occurred in 35 (56%) DHV grafts and 78 (1.24 per py) in 36 (53%) PTFE grafts. A total of nine infections were seen in nine (14%) DHV grafts, whereas 21 infections in 20 (29%) PTFE grafts were seen (p=0.08). All but one infected DHV graft could be salvaged with systemic antibiotics. In contrast, surgical intervention was necessary in nine PTFE grafts (p=0.02). For aneurysms, eight DHV and two PTFE grafts needed revision (p=0.03). Conclusion: Patency rates between DHV and PTFE were not different. More infections were seen in PTFE grafts, and significantly more PTFE grafts needed surgical revision or removal because of infection. Significantly more DHV grafts were surgically revised or removed because of aneurysms.
引用
收藏
页码:126 / 132
页数:7
相关论文
共 40 条
[11]  
Eikelboom B C, 1988, Eur J Vasc Surg, V2, P1, DOI 10.1016/S0950-821X(88)80098-7
[12]   A preliminary experience with the human homologous vein graft for vascular access [J].
Gecim, IE ;
Ward, RG ;
Bakran, A ;
Aikawa, A ;
Sells, RA .
VASCULAR SURGERY, 1996, 30 (05) :395-398
[13]  
HAIMOV M, 1974, SURGERY, V75, P447
[14]   PREVENTION OF THROMBOSIS IN PATIENTS ON HEMODIALYSIS BY LOW-DOSE ASPIRIN [J].
HARTER, HR ;
BURCH, JW ;
MAJERUS, PW ;
STANFORD, N ;
DELMEZ, JA ;
ANDERSON, CB ;
WEERTS, CA .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (11) :577-579
[15]   THE RESULTS OF DENATURED HOMOLOGOUS VEIN GRAFTS AS CONDUITS FOR SECONDARY HEMODIALYSIS ACCESS SURGERY [J].
HEINTJES, RJ ;
EIKELBOOM, BC ;
STEIJLING, JJF ;
DORTLAND, RWHV ;
VANDERHEIJDEN, FHWM ;
BASTINI, M ;
VANDERGRAAF, Y ;
BLANKESTIJN, PJ ;
VOS, J .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1995, 9 (01) :58-63
[16]   COMPARISON OF AUTOGENOUS FISTULA VERSUS EXPANDED POLYTETRAFLUOROETHYLENE GRAFT FISTULA FOR ANGIOACCESS IN HEMODIALYSIS [J].
KHERLAKIAN, GM ;
ROEDERSHEIMER, LR ;
ARBAUGH, JJ ;
NEWMARK, KJ ;
KING, LR .
AMERICAN JOURNAL OF SURGERY, 1986, 152 (02) :238-243
[17]   PREDICTIVE VALUE OF COLOR DOPPLER ULTRASONOGRAPHY IN DETECTING FAILURE OF VASCULAR ACCESS GRAFTS [J].
KOKSOY, C ;
KUZU, A ;
ERDEN, I ;
TURKCAPAR, AG ;
DUZGUN, I ;
ANADOL, E .
BRITISH JOURNAL OF SURGERY, 1995, 82 (01) :50-52
[18]  
LACOMBE M, 1973, J UROL NEPHROL, V79, P537
[19]  
Masselot J P, 1977, Proc Eur Dial Transplant Assoc, V14, P633
[20]   POLYTETRAFLUOROETHYLENE (PTFE) GRAFTS FOR HEMODIALYSIS - PATENCY AND COMPLICATIONS COMPARED WITH THOSE OF SAPHENOUS-VEIN GRAFTS [J].
MAY, J ;
HARRIS, J ;
PATRICK, W .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1979, 49 (06) :639-642