Fat suppression for 1H MRSI at 7T using spectrally selective adiabatic inversion recovery

被引:37
作者
Balchandani, Priti [1 ,2 ]
Spielman, Daniel [2 ]
机构
[1] Stanford Univ, Lucas Ctr MR Spect, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
MRSI; adiabatic; inversion recovery; fat suppression; 7T; spatial-spectral;
D O I
10.1002/mrm.21537
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Proton magnetic resonance spectroscopic imaging (H-1 MRSI) at 7T offers many advantages, including increased SNR and spectral resolution. However, technical difficulties associated with operating at high fields, such as increased B-1 and B-0 inhomogenelty, severe chemical shift localization error, and converging T, values, make the suppression of the broad lipid peaks which can obscure targeted metabolite signals, particularly challenging. Conventional short tau inversion recovery can successfully suppress fat without restricting the selected volume, but only with significant metabolite signal loss. In this work, we have designed two new pulses for frequency-selective inversion recovery that achieve B-1 -insensitive fat suppression without degrading the signal from the major metabolites of interest. The first is a spectrally selective adiabatic pulse to be used in a volumetric H-1 MRSI sequence and the second is a spatial-spectral adiabatic pulse geared toward multi-slice H-1 MRSI. Partial interior volume selection may be used in addition to the pulses, to exclude areas with severe B-0 inhomogeneity. Some differences in the spectral profile as well as degree of suppression make each pulse valuable for different applications. 7T phantom and in vivo data show that both pulses significantly suppress fat, while leaving most of the metabolite signal intact.
引用
收藏
页码:980 / 988
页数:9
相关论文
共 17 条
[1]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[2]   MRI: Use of the inversion recovery pulse sequence [J].
Bydder, GM ;
Hajnal, JV ;
Young, IR .
CLINICAL RADIOLOGY, 1998, 53 (03) :159-176
[3]   2-DIMENSIONAL SELECTIVE ADIABATIC PULSES [J].
CONOLLY, S ;
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1992, 24 (02) :302-313
[4]   Adiabatic water suppression using frequency selective excitation [J].
de Graaf, RA ;
Nicolay, K .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (05) :690-696
[5]   MAPPING OF THE RADIOFREQUENCY FIELD [J].
INSKO, EK ;
BOLINGER, L .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 103 (01) :82-85
[6]   Dynamic shim updating on the human brain [J].
Koch, Kevin M. ;
McIntyre, Scott ;
Nixon, Terence W. ;
Rothman, Douglas L. ;
de Graaf, Robin A. .
JOURNAL OF MAGNETIC RESONANCE, 2006, 180 (02) :286-296
[7]   BISTRO:: An outer-volume suppression method that tolerates RF field inhomogeneity [J].
Luo, Y ;
de Graaf, RA ;
DelaBarre, L ;
Tannús, A ;
Garwood, M .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1095-1102
[8]   SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION [J].
MEYER, CH ;
PAULY, JM ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) :287-304
[9]   Dynamic shimming for multi-slice magnetic resonance imaging [J].
Morrell, G ;
Spielman, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :477-483
[10]   MR spectroscopy: Truly molecular imaging; Past present and future [J].
Mullins, Mark E. .
NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (04) :605-+