Dynamic shimming for multi-slice magnetic resonance imaging

被引:78
作者
Morrell, G [1 ]
Spielman, D [1 ]
机构
[1] STANFORD UNIV,MED CTR,DEPT RADIOL,STANFORD,CA 94305
关键词
dynamic shimming; fat saturation; echo-planar imaging; spiral imaging; TIME-VARYING GRADIENTS; GEOMETRIC DISTORTION; FIELD INHOMOGENEITIES; MR-IMAGES; RESTORATION; ARTIFACTS; MAP; FAT;
D O I
10.1002/mrm.1910380316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic shimming has been implemented in three pulse sequences on a commercial GE Signa 1.5-T imaging system. Multi-slice field maps are acquired before the imaging sequence, and linear shim terms and center frequencies are calculated for each slice. During the imaging scan, the linear shim terms and center frequency are set before each pulse sequence repetition according to the current slice. Acquisition of multi-slice field maps and calculation of shim terms and center frequency for each slice are accomplished in a matter of seconds. Pulse sequences require only minimal modification to add dynamic shimming capability. Results are shown for a fat saturation spin-echo sequence, a single-shot echo-planar gradient-recalled echo sequence, and a spiral acquisition gradient-recalled echo sequence. In all cases, dynamic shimming with shim currents and center frequency optimized for each slice is shown to give better results than constant shim currents and a single center frequency optimized for the entire volume of interest.
引用
收藏
页码:477 / 483
页数:7
相关论文
共 37 条
[1]  
ANZAI Y, 1992, AM J NEURORADIOL, V13, P879
[2]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[3]  
BLAMIRE A, 1995, P SMRM 3 ANN M NIC A, P802
[4]   Dynamic shim updating: A new approach towards optimized whole brain shimming [J].
Blamire, AM ;
Rothman, DL ;
Nixon, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :159-165
[5]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[6]   ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[7]   MAGNETIC-RESONANCE-IMAGING WITH NONUNIFORM FIELDS [J].
FEIG, E ;
GREENLEAF, F ;
PERLIN, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (10) :1091-1099
[8]   AUTOMATIC, LOCALIZED INVIVO ADJUSTMENT OF ALL 1ST-ORDER AND 2ND-ORDER SHIM COILS [J].
GRUETTER, R .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :804-811
[9]   AUTOMATIC SHIMMING FOR LOCALIZED SPECTROSCOPY [J].
HOLZ, D ;
JENSEN, D ;
PROKSA, R ;
TOCHTROP, M ;
VOLLMANN, W .
MEDICAL PHYSICS, 1988, 15 (06) :898-903
[10]  
HOWE FA, 1993, MAGN RESON QUART, V9, P31