Evaluation of a novel pad printing technique for the fabrication of disposable electrode assemblies

被引:18
作者
Mooring, L
Karousos, NG
Livingstone, C
Davis, J [1 ]
Wildgoose, GG
Wilkins, SJ
Compton, RG
机构
[1] Univ Surrey, Sch Biomed & Mol Sci, Guildford GU2 7XH, Surrey, England
[2] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
[3] Univ Oxford, Dept Mat Sci, Oxford OX1 3QZ, England
基金
英国工程与自然科学研究理事会;
关键词
carbon; ink; sensor; disposable; electrode;
D O I
10.1016/j.snb.2004.11.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The viability of using a pad printing, technique for the production of disposable electrode systems has been assessed. The morphology and structural characteristics of the carbon ink layers has been characterised and the electrochemical behaviour of the resulting layers investigated using a number of model systems. Voltammetric and potentiometric methodologies (in aqueous buffer and acetonitrile) were conducted using ferrocence carboxylic acid and naphthoquinone-thiol systems. The ability to create modified electrode assemblies through the incorporation of indicators directly within the ink prior to printing has been shown to provide a facile means through which the selectivity of the electrodes can be enhanced and provides a quick means of prototyping reagentless sensors. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:491 / 496
页数:6
相关论文
共 22 条
[1]   Configurations used in the design of screen-printed enzymatic biosensors.: A review [J].
Albareda-Sirvent, M ;
Merkoçi, A ;
Alegret, S .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) :153-163
[2]   Systematic review of near patient test evaluations in primary care [J].
Delaney, BC ;
Hyde, CJ ;
McManus, RJ ;
Wilson, S ;
Fitzmaurice, DA ;
Jowett, S ;
Tobias, R ;
Thorpe, GH ;
Hobbs, FDR .
BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7213) :824-827
[3]   Printed analogue filter structures [J].
Evans, PSA ;
Ramsey, BJ ;
Harrey, PM ;
Harrison, DJ .
ELECTRONICS LETTERS, 1999, 35 (04) :306-308
[4]   RF circulator structures via offset lithography [J].
Evans, PSA ;
Harrey, PM ;
Ramsey, BJ ;
Harrison, DJ .
ELECTRONICS LETTERS, 1999, 35 (19) :1634-1636
[5]  
EVANS PSA, 1997, J ELECTRON MANUF, V7, P63
[6]   Development of a disposable potentiometric sensor for the near patient testing of plasma thiol concentrations [J].
Gracheva, S ;
Livingstone, C ;
Davis, J .
ANALYTICAL CHEMISTRY, 2004, 76 (13) :3833-3836
[7]  
GRACHEVA S, IN PRESS ELECTROANAL
[8]   Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses [J].
Hart, JP ;
Wring, SA .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (02) :89-103
[9]   Near patient testing: Is it here to stay? [J].
Hicks, JM .
JOURNAL OF CLINICAL PATHOLOGY, 1996, 49 (03) :191-193
[10]   The laboratory-clinical interface - Point-of-care testing [J].
Kost, GJ ;
Ehrmeyer, SS ;
Chernow, B ;
Winkelman, JW ;
Zaloga, GP ;
Dellinger, RR ;
Shirey, T .
CHEST, 1999, 115 (04) :1140-1154