A cost-analysis of computed radiography and picture archiving and communication systems in portable radiography

被引:8
作者
Huda, W [1 ]
Honeyman, JC [1 ]
Frost, MM [1 ]
Staab, EV [1 ]
机构
[1] UNIV FLORIDA,COLL MED,DEPT RADIOL,GAINESVILLE,FL 32610
关键词
computed radiography (CR); picture archiving and communication system (PACS); cost analysis;
D O I
10.1007/BF03168567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A total of 40,000 portable examinations are performed each year at Shands Hospital (Gainesville, FL), a 570-bed teaching hospital. Radiographs are obtained using a screen-film combination with the films digitized for transmission to displays in four intensive care units. A cost-analysis of replacing screen-film with computed radiography (CR) integrated into a filmless picture archiving and communication system (PACS) network was performed. Equipment requirements included two CR units, three high-resolution dual monitor displays, and an archive to store 3 months of image data. The capital costs were amortized over a 5-year period. Capital and operating costs of the proposed expansion to the existing PACS network, together with anticipated cost savings, were determined. The maximum data transfer rate for portable examinations was 150 MByte per hour and approximately 400 GByte of image data are generated each year. These figures were used to determine the hardware requirements for handling the acquisition, transfer, and display of the images. Annual costs of the proposed expansion were about $220,000. Cost savings were achieved by elimination of film, including its handling by technologists/library clerks, and amounted to about $200,000 per year. Copyright (C) 1996 by W.B. Saunders Company
引用
收藏
页码:39 / 44
页数:6
相关论文
共 19 条
[1]  
BRYAN S, 1993, SPIE MED IMAGING, V1899, P434
[2]   THE ECONOMIC-IMPACT OF TECHNOLOGY ON DIAGNOSTIC-IMAGING AT A UNIVERSITY MEDICAL-CENTER [J].
EVENS, RG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (01) :179-183
[3]   POTENTIAL CLINICAL PROBLEMS ASSOCIATED WITH PACS [J].
FRIEDENBERG, RM .
RADIOLOGY, 1993, 189 (01) :A55-A57
[4]  
Gillespy T 3rd, 1990, J Digit Imaging, V3, P124
[5]  
GREINACHER CFC, 1994, P SOC PHOTO-OPT INS, V2165, P490, DOI 10.1117/12.174338
[6]  
HONEYMAN JC, 1995, SPIE MED IMAGING, V2431, P530
[7]   PRELIMINARY EXPERIENCE WITH PORTABLE DIGITAL IMAGING FOR INTENSIVE-CARE RADIOGRAPHY [J].
MARGLIN, SI ;
ROWBERG, AH ;
GODWIN, JD .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :49-54
[8]  
MOSSER H, 1994, S F, V3038
[9]   PORTABLE CHEST IMAGING - COMPARISON OF STORAGE PHOSPHOR DIGITAL, ASYMMETRIC SCREEN-FILM, AND CONVENTIONAL SCREEN-FILM SYSTEMS [J].
NIKLASON, LT ;
CHAN, HP ;
CASCADE, PN ;
CHANG, CL ;
CHEE, PW ;
MATHEWS, JF .
RADIOLOGY, 1993, 186 (02) :387-393
[10]  
PITT R, 1994, SPIE MED IMAGING, V2164, P210