Chemotaxis in microfluidic devices -: a study of flow effects

被引:26
作者
Beta, Carsten [1 ,2 ]
Froehlich, Toni [1 ]
Boedeker, Hendrik U. [3 ]
Bodenschatz, Eberhard [1 ]
机构
[1] Max Planck Inst Dynam & Selbstorganisat, D-37077 Gottingen, Germany
[2] Univ Potsdam, Inst Phys & Astron, D-14476 Potsdam, Germany
[3] WWU Munster, Inst Angew Phys, D-48149 Munster, Germany
关键词
D O I
10.1039/b801331d
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of microfluidic devices has become increasingly popular in the study of chemotaxis due to the exceptional control of flow properties and concentration profiles on the length scale of individual cells. In these applications, it is often neglected that cells, attached to the inner surfaces of the microfluidic chamber, are three-dimensional objects that perturb and distort the flow field in their vicinity. Depending on the interplay of flow speed and geometry with the diffusive time scale of the chemoattractant in the flow, the concentration distribution across the cell membrane may differ strongly from the optimal gradient in a perfectly smooth channel. We analyze the underlying physics in a two-dimensional approximation and perform systematic numerical finite element simulations to characterize the three-dimensional case and to identify optimal flow conditions.
引用
收藏
页码:1087 / 1096
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 2014, SCI TRANSL MED, DOI DOI 10.1126/scitranslmed.3009337
[2]  
Berg HC., 2003, E. coli in motion
[3]   Flow photolysis for spatiotemporal stimulation of single cells [J].
Beta, Carsten ;
Wyatt, Danica ;
Rappel, Wouter-Jan ;
Bodenschatz, Eberhard .
ANALYTICAL CHEMISTRY, 2007, 79 (10) :3940-3944
[4]   DIFFUSION OF ADENOSINE TRIPHOSPHATE THROUGH AQUEOUS SOLUTIONS [J].
BOWEN, WJ ;
MARTIN, HL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1964, 107 (01) :30-&
[6]   Microfluidics-based systems biology [J].
Breslauer, DN ;
Lee, PJ ;
Lee, LP .
MOLECULAR BIOSYSTEMS, 2006, 2 (02) :97-112
[7]   Generation of complex concentration profiles in microchannels in a logarithmically small number of steps [J].
Campbell, Kyle ;
Groisman, Alex .
LAB ON A CHIP, 2007, 7 (02) :264-272
[8]   Intravital imaging of cell movement in tumours [J].
Condeelis, J ;
Segall, JE .
NATURE REVIEWS CANCER, 2003, 3 (12) :921-930
[9]   Generation of gradients having complex shapes using microfluidic networks [J].
Dertinger, SKW ;
Chiu, DT ;
Jeon, NL ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1240-1246
[10]   Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients [J].
Irimia, D ;
Liu, SY ;
Tharp, WG ;
Samadani, A ;
Toner, M ;
Poznansky, MC .
LAB ON A CHIP, 2006, 6 (02) :191-198