Locating the motor cortex on the MRI with transcranial magnetic stimulation and PET

被引:161
作者
Wassermann, EM [1 ]
Wang, BS [1 ]
Zeffiro, TA [1 ]
Sadato, N [1 ]
PascualLeone, A [1 ]
Toro, C [1 ]
Hallett, M [1 ]
机构
[1] NIH, NATL CTR RES RESOURCES, BIOMED ENGN & INSTRUMENTAT PROGRAM, BETHESDA, MD 20892 USA
关键词
D O I
10.1006/nimg.1996.0001
中图分类号
Q189 [神经科学];
学科分类号
071006 [神经生物学];
摘要
Transcranial magnetic stimulation with a focal coil was used to map the cortical representation of a hand muscle in four healthy subjects, In each subject, the three-dimensional locations of the magnetic stimulation positions and about 400 positions on the surface of the head were digitized, The amplitude-weighted center of gravity of each subject's map was found, and a line perpendicular to the local head surface was projected inward, The digitized heads were registered with the subjects' MRIs using the scalp contours, The coordinate transformations yielded by this process were used to map the stimulation positions and the perpendicular line into the MRIs, Brain areas imaged with positron emission tomography (PET) and O-15-labeled water, activated by movement of the same muscle, were registered with the MRIs using the brain contours, In all cases, the magnetic stimulation lines encountered the surface of the brain at the anterior lip of the central sulcus and ran along the precentral gyrus a few millimeters anterior to the central sulcus, coming within 5-22 mm of all the PET activation maxima, This technique demonstrates the accuracy of transcranial magnetic stimulation for locating the primary motor area. (C) 1996 Academic Press, Inc.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 40 条
[1]
AMASSIAN VE, 1987, NEUROSURGERY, V20, P148
[2]
AMASSIAN VE, 1987, J PHYSIOL-LONDON, V394, pP119
[3]
AMASSIAN VE, 1989, MAGNETIC STIMULATION, P73
[4]
[Anonymous], 1954, JAMA-J AM MED ASSOC
[5]
BARKER AT, 1985, LANCET, V1, P1106
[6]
CORRELATION OF MOTOR CORTEX-BRAIN MAPPING DATA WITH MAGNETIC-RESONANCE-IMAGING [J].
BERGER, MS ;
COHEN, WA ;
OJEMANN, GA .
JOURNAL OF NEUROSURGERY, 1990, 72 (03) :383-387
[7]
TOPOGRAPHIC MAPPING OF THE HUMAN MOTOR CORTEX WITH MAGNETIC STIMULATION - FACTORS AFFECTING ACCURACY AND REPRODUCIBILITY [J].
BRASILNETO, JP ;
MCSHANE, LM ;
FUHR, P ;
HALLETT, M ;
COHEN, LG .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 85 (01) :9-16
[8]
PREOPERATIVE LOCALIZATION OF THE CENTRAL SULCUS BY DIPOLE SOURCE ANALYSIS OF EARLY SOMATOSENSORY-EVOKED POTENTIALS AND 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING [J].
BUCHNER, H ;
ADAMS, L ;
KNEPPER, A ;
RUGER, R ;
LABORDE, G ;
GILSBACH, JM ;
LUDWIG, I ;
REUL, J ;
SCHERG, M .
JOURNAL OF NEUROSURGERY, 1994, 80 (05) :849-856
[9]
EFFECTS OF COIL DESIGN ON DELIVERY OF FOCAL MAGNETIC STIMULATION - TECHNICAL CONSIDERATIONS [J].
COHEN, LG ;
ROTH, BJ ;
NILSSON, J ;
DANG, N ;
PANIZZA, M ;
BANDINELLI, S ;
FRIAUF, W ;
HALLETT, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 75 (04) :350-357
[10]
COHEN LG, 1990, MAGNETIC STIMULATION, P113