Factors influencing the development of vein-graft stenosis and their significance for clinical management

被引:49
作者
Idu, MM [1 ]
Buth, J [1 ]
Hop, WCJ [1 ]
Cuypers, P [1 ]
van de Pavoordt, EDWM [1 ]
Tordoir, JMH [1 ]
机构
[1] Univ Hosp Maastricht, Dept Surg, Maastricht, Netherlands
关键词
infrainguinal vein graft; vein-graft stenosis; graft surveillance; graft factors;
D O I
10.1053/ejvs.1998.0676
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: to assess the influence of clinical and graft factors on the development of stenotic lesions. In addition the implications of any significant correlation for duplex surveillance schedules ol surgical bypass techniques was examined. Patients and methods: in a prospective three centre study, preoperative and peroperative data on 300 infrainguinal autologous vein grafts was analysed. All grafts were monitored by a strict duplex surveillance program and all received an angiogram in the first postoperative year. A revision was only performed if there was evidence of a stenosis of 70% diameter reduction or greater on the angiogram. Results: the minimum graft diameter sons the only factor correlated significantly with the development of a significant graft stenosis (PSV-ratio greater than or equal to 2.5) during follow-up (p = 0.002). Factors that correlated with the development of event-causing graft stenosis, associated with revision or occlusion, were minimal graft diameter (p = 0.001), the use of a venovenous anastomosis (p = 0.005) and length of the graft (p = 0.025). Multivariate regression analysis revealed that the minimal graft diameter was the only independent factor that significantly correlated with an event-causing graft stenosis (p = 0.009). The stenosis-free rates for grafts with a minimal diameter <3.5 mm, between 3.5-4.5 and greater than or equal to 4.5 mm were 40%, 58% and 75%, respectively (p = <0.05). Composite vein and arm-vein grafts with minimal diameters greater than or equal to 3.5 mm were compared with grafts which consisted of a single uninterrupted greater saphenous vein with a minimal diameter of <3.5 mm. One-year secondary patency rates in these categories were of 94% and 76%, respectively (p = 0.03). Conclusions: a minimal graft diameter <3.5 mm was the only factor that significantly correlated with the development of a graft-stenosis. However, veins with larger diameters may still develop stenotic lesions. Composite vein and arm-vein grafts should be used rather than uninterrupted small caliber saphenous veins.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 40 条
[21]   SAPHENOUS-VEIN BIOPSY - A PREDICTOR OF VEIN GRAFT FAILURE [J].
MARIN, ML ;
VEITH, FJ ;
PANETTA, TF ;
GORDON, RE ;
WENGERTER, KR ;
SUGGS, WD ;
SANCHEZ, L ;
PARIDES, MK ;
GOLDMAN, MH ;
LUMSDEN, A ;
ZARINS, C ;
MILLS, J .
JOURNAL OF VASCULAR SURGERY, 1993, 18 (03) :407-415
[22]  
MOHAN CR, 1995, ARCH SURG-CHICAGO, V130, P483
[23]  
Moody P, 1990, Eur J Vasc Surg, V4, P117, DOI 10.1016/S0950-821X(05)80424-4
[24]   FEMOROCRURAL GRAFTING AND REGRAFTING - DOES POLYTETRAFLUOROETHYLENE HAVE A ROLE [J].
MORRIS, GE ;
RAPTIS, S ;
MILLER, JH ;
FARIS, IB .
EUROPEAN JOURNAL OF VASCULAR SURGERY, 1993, 7 (03) :329-334
[25]   UNSUSPECTED PREEXISTING SAPHENOUS-VEIN DISEASE - AN UNRECOGNIZED CAUSE OF VEIN BYPASS FAILURE [J].
PANETTA, TF ;
MARIN, ML ;
VEITH, FJ ;
GOLDSMITH, J ;
GORDON, RE ;
JONES, AM ;
SCHWARTZ, ML ;
GUPTA, SK ;
WENGERTER, KR .
JOURNAL OF VASCULAR SURGERY, 1992, 15 (01) :102-112
[26]   Polytetrafluoroethylene bypasses to infrapopliteal arteries without cuffs or patches: A better option than amputation in patients without autologous vein [J].
Parsons, RE ;
Suggs, WD ;
Veith, FJ ;
Sanchez, LA ;
Lyon, RT ;
Marin, ML ;
Goldsmith, J ;
Faries, PL ;
Wengerter, KR ;
Schwartz, ML .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (02) :347-354
[27]   LONG-TERM RESULTS OF INFRAGENICULAR BYPASSES WITH AUTOGENOUS VEIN ORIGINATING FROM THE DISTAL SUPERFICIAL FEMORAL AND POPLITEAL ARTERIES [J].
ROSENBLOOM, MS ;
WALSH, JJ ;
SCHULER, JJ ;
MEYER, JP ;
SCHWARCZ, TH ;
ELDRUPJORGENSEN, J ;
DURHAM, JR ;
FLANIGAN, DP .
JOURNAL OF VASCULAR SURGERY, 1988, 7 (05) :691-696
[28]  
RUTHERFORD RB, 1986, J VASC SURG, V4, P80
[29]   EXPERIENCE WITH 130 POLYTETRAFLUOROETHYLENE GRAFTS [J].
SLADEN, JG ;
MAXWELL, TM .
AMERICAN JOURNAL OF SURGERY, 1981, 141 (05) :546-548
[30]  
SZILAGYI DE, 1973, ANN SURG, V178, P232, DOI 10.1097/00000658-197309000-00002