A low-cost multi-channel aerosol fluorescence sensor for networked deployment

被引:16
作者
Kaye, PH [1 ]
Hirst, E [1 ]
Foot, V [1 ]
Clark, JM [1 ]
Baxter, K [1 ]
机构
[1] Univ Hertfordshire, Sci & Technol Res Inst, Hatfield AL10 9AB, Herts, England
来源
OPTICALLY BASED BIOLOGICAL AND CHEMICAL SENSING FOR DEFENCE | 2004年 / 5617卷
关键词
bio-aerosol; fluorescence; xenon; sensor; network;
D O I
10.1117/12.578283
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a low-cost prototype bio-aerosol fluorescence sensor designed for unattended deployment in medium to large area networks. The sensor uses two compact xenon flash units to excite fluorescence in an aerosol sample volume drawn continuously from the ambient environment. In operation, the xenons are pulsed alternately at 300ms intervals whilst absorption filters restrict their radiation output to UV bands similar to260-290nm and similar to340-380nm respectively, optimal for exciting the biological fluorophores tryptophan and NADH. Fluorescence from all particles instantaneously present within a sensing volume is measured using two miniature photomultiplier detectors optically filtered to detect radiation in the bands similar to320-600nm and similar to410-600nm. The second of these bands covers the principal emission from NADH, whilst the difference between the first and second detector channels yields fluorescence in the 320-410nm band, covering much of the tryptophan emission. Whilst each sensor is clearly limited in specificity, the low sensor cost (<$5k) offers potential for the deployment in large networks that would be prohibitively expensive using particle fluorescence sensors based on currently available UV lasers. Preliminary details are also given of a variant of the sensor, currently under development, in which xenon illumination is used to acquire single particle fluorescence data at rates of up to 200 particles per second.
引用
收藏
页码:388 / 398
页数:11
相关论文
共 8 条
[1]   Conditional-firing aerosol-fluorescence spectrum analyzer for individual airborne particles with pulsed 266-nm laser excitation [J].
Chen, G ;
Nachman, P ;
Pinnick, RG ;
Hill, SC ;
Chang, RK .
OPTICS LETTERS, 1996, 21 (16) :1307-1309
[2]   Design of an instrument for real-time detection of bioaerosols using simultaneous measurement of particle aerodynamic size and intrinsic fluorescence [J].
Hairston, PP ;
Ho, J ;
Quant, FR .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (03) :471-482
[3]   Development of a UV LED based biosensor [J].
Jeys, TH ;
Desmarais, L ;
Lynch, EJ ;
Ochoa, JR .
SENSORS, AND COMMAND, CONTROL, COMMUNICATIONS, AND INTELLIGENCE (C3I) TECHNOLOGIES FOR HOMELAND DEFENSE AND LAW ENFORCEMENT II, 2003, 5071 :234-240
[4]   Simultaneous light scattering and intrinsic fluorescence measurement for the classification of airborne particles [J].
Kaye, PH ;
Barton, JE ;
Hirst, E ;
Clark, JM .
APPLIED OPTICS, 2000, 39 (21) :3738-3745
[5]   FLUORESCENCE PARTICLE COUNTER FOR DETECTING AIRBORNE BACTERIA AND OTHER BIOLOGICAL PARTICLES [J].
PINNICK, RG ;
HILL, SC ;
NACHMAN, P ;
PENDLETON, JD ;
FERNANDEZ, GL ;
MAYO, MW ;
BRUNO, JG .
AEROSOL SCIENCE AND TECHNOLOGY, 1995, 23 (04) :653-664
[6]  
Reyes FL, 1999, FIELD ANAL CHEM TECH, V3, P240, DOI 10.1002/(SICI)1520-6521(1999)3:4/5<240::AID-FACT3>3.0.CO
[7]  
2-#
[8]   Size and fluorescence measurements for field detection of biological aerosols [J].
Seaver, M ;
Eversole, JD ;
Hardgrove, JJ ;
Cary, WK ;
Roselle, DC .
AEROSOL SCIENCE AND TECHNOLOGY, 1999, 30 (02) :174-185