Accurate frequency measurement of a submillimeter wave gyrotron output using a far-infrared laser as a reference

被引:8
作者
Idehara, T
Mitsudo, S
Saito, S
Ogawa, I
Okajima, S
机构
[1] Fukui Univ, Res Ctr Dev Far Infrared Reg, Fukui 9108507, Japan
[2] Fukui Univ, Cryogen Lab, Fac Engn, Fukui 9108507, Japan
[3] Chubu Univ, Coll Engn, Aichi 4878501, Japan
关键词
D O I
10.1063/1.1568549
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate measurement of gyrotron frequency has been carried out by using a far-infrared (FIR) molecular laser as a reference. Highly stable operation of a FIR laser enables us to make the resolution of frequency measurement so precisely that both the frequency width Deltaf and the frequency fluctuation level deltaf can be studied within the accuracy of 1 kHz or less. When our submillimeter wave gyrotron operates in cw mode, the observed frequency width Deltaf is around 2 kHz and the fluctuation level deltaf 10 kHz. Such an accurate measurement is a useful tool for development of high quality gyrotrons with stable frequency. (C) 2003 American Institute of Physics.
引用
收藏
页码:2860 / 2862
页数:3
相关论文
共 7 条
[1]   Effect of technical noise on radiation linewidth in free-running gyrotron oscillators [J].
Dumbrajs, O ;
Nusinovich, GS .
PHYSICS OF PLASMAS, 1997, 4 (05) :1413-1423
[2]   Development of frequency tunable, medium power gyrotrons (Gyrotron FU series) as submillimeter wave radiation sources [J].
Idehara, T ;
Ogawa, I ;
Mitsudo, S ;
Pereyaslavets, M ;
Nishida, N ;
Yoshida, K .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (02) :340-354
[3]   HIGH-FREQUENCY, STEP TUNABLE, CYCLOTRON HARMONIC GYROTRON [J].
IDEHARA, T ;
TATSUKAWA, T ;
TANABE, H ;
MATSUMOTO, S ;
KUNIEDA, K ;
HEMMI, K ;
KANEMAKI, T .
PHYSICS OF FLUIDS B-PLASMA PHYSICS, 1991, 3 (07) :1766-1772
[4]   High power, frequency tunable, submillimeter wave ESR device using a gyrotron as a radiation source [J].
Mitsudo S. ;
Aripin ;
Shirai T. ;
Matsuda T. ;
Kanemaki T. ;
Idehara T. .
International Journal of Infrared and Millimeter Waves, 2000, 21 (04) :661-676
[5]   LONG-PULSE OPERATION OF A SUBMILLIMETER-WAVE GYROTRON AND ITS APPLICATION TO PLASMA SCATTERING MEASUREMENT [J].
OGAWA, I ;
YOSHISUE, K ;
IBE, H ;
IDEHARA, T ;
KAWAHATA, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (05) :1788-1789
[6]   Development of submillimeter wave catheter transmitting a GYROTRON output for irradiation on living bodies [J].
Tatsukawa, T ;
Doi, A ;
Teranaka, M ;
Takashima, H ;
Goda, F ;
Idehara, T ;
Ogawa, I ;
Mitsudo, S ;
Kanemaki, T .
INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 21 (08) :1155-1167
[7]  
TERUMICHI Y, 1984, 9 INT C INFR MILL WA, P411