The H-point and generalized H-point standard additions methods for flow injection procedures

被引:27
作者
Campins-Falco, P [1 ]
Gomez, FB [1 ]
Bosch-Reig, F [1 ]
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Burjassot, Spain
关键词
flow injection; blank bias error; chloride determination; calcium and magnesium determination;
D O I
10.1016/S0039-9140(98)00067-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper establishes the fundamentals of the H-point standard additions method (HPSAM) and generalized I-I-point standard additions method (GHPSAM) in the flow injection technique. Two kinds of analytical signals can be employed, FIA peaks and spectra. Different analytical problems have been studied: determinations of one analyte in the presence or absence of matrix effect when different blank features are present, and determination of two analytes in the presence of blank bias error affecting the development of one of them. The determination of chloride with mercury thiocyanate which presents a matrix effect, and the determinations of calcium and/or magnesium with arsenate III are examined. The methods were compared with conventional data treatment and proved able to isolate the analyte signal from the global one, thus providing accurate and precise results in the determination of the above mentioned species in bottled waters. No additional experimental work is needed to apply the methods. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 8 条
[1]   H-POINT STANDARD ADDITIONS METHOD FOR ANALYTE DETERMINATION IN TERNARY MIXTURES [J].
ANDRES, JV ;
REIG, FB ;
FALCO, PC .
ANALYST, 1995, 120 (02) :299-304
[2]   STUDY OF THE BEHAVIOR OF THE ABSORBENT BLANKS IN ANALYTICAL PROCEDURES BY USING THE H-POINT STANDARD ADDITIONS METHOD (HPSAM) [J].
BOSCHREIG, F ;
VERDUANDRES, J ;
CAMPINSFALCO, P ;
MOLINSLEGUA, C .
TALANTA, 1994, 41 (01) :39-52
[3]   EVALUATION AND ELIMINATION OF THE BLANK BIAS ERROR USING THE H-POINT STANDARD ADDITION METHOD - APPLICATION TO SPECTROPHOTOMETRIC DETERMINATIONS USING ABSORBENT BLANK [J].
CAMPINSFALCO, P ;
BOSCHREIG, F ;
VERDUANDRES, J .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :253-265
[4]   Evaluation and elimination of the blank bias error using the H-point standard additions method (HPSAM) in the simultaneous spectrophotometric determination of two analytes [J].
CampinsFalco, P ;
VerduAndres, J ;
BoschReig, F .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :39-49
[5]  
FALCO PC, 1995, ANAL CHIM ACTA, V302, P323
[6]   Flow injection spectrophotometric determination of ng ml(-1) levels of cobalt(II) using the photochemical decomposition of a cadmium(II)-water-soluble porphyrin complex [J].
Igarashi, S ;
Aihara, T ;
Yotsuyanagi, T .
ANALYTICA CHIMICA ACTA, 1996, 323 (1-3) :63-67
[7]   H-POINT STANDARD ADDITIONS METHOD .1. FUNDAMENTALS AND APPLICATION TO ANALYTICAL SPECTROSCOPY [J].
REIG, FB ;
FALCO, PC .
ANALYST, 1988, 113 (07) :1011-1016
[8]  
REIG FB, 1990, ANALYST, V115, P111