Improvement of the spatial resolution of the ACIS using split-pixel events

被引:80
作者
Tsunemi, H
Mori, K
Miyata, E
Baluta, C
Burrows, DN
Garmire, GP
Chartas, G
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, Osaka 5600043, Japan
[2] Penn State Univ, Dept Astron & Astrophys, Davey Lab 525, University Pk, PA 16802 USA
关键词
instrumentation : detectors; methods : data analysis; techniques : image processing; X-ray : general;
D O I
10.1086/321338
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The position accuracy of X-ray photons on a CCD detector is generally believed to be limited by the CCD pixel size. While this is true in general, the position accuracy for X-ray events which deposit charge in more than one pixel can be better than that of the CCD pixel size. Since the position uncertainty for corner events is much better than the pixel size, we can improve the Chandra ACIS spatial resolution by selecting only these events. We have analyzed X-ray images obtained with the Chandra ACIS for six pointlike sources observed near the optical axis. The image quality near the optical axis is characterized by a half-power diameter (HPD) of 0."66 that is a convolution of the point-spread function (PSF) of the high-resolution mirror assembly (HRMA) and the CCD pixel shape (24 mum square). By considering only corner events the image quality is improved to 0."56 (HPD) at the optical axis, which is very close to the image quality of the HRMA alone. We estimated the degradation of the image quality obtained by using all events, compared to that obtained using only corner events, to be 0."33, which coincides with that expected from the pixel size. Since the fraction of the corner events is relatively small, this technique requires correspondingly longer exposure time to achieve good statistics.
引用
收藏
页码:496 / 504
页数:9
相关论文
共 11 条
[1]   Soft-x-ray CCD imagers for AXAF [J].
Burke, BE ;
Gregory, JA ;
Bautz, MW ;
Prigozhin, GY ;
Kissel, SE ;
Kosicki, BB ;
Loomis, AH ;
Young, DJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (10) :1633-1642
[2]   Subpixel spatial resolution of the X-ray charge-coupled device based on the charge cloud shape [J].
Hiraga, J ;
Tsunemi, H ;
Miyata, E .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2001, 40 (3A) :1493-1498
[3]   How big are charge clouds inside the charge-coupled device produced by X-ray photons? [J].
Hiraga, J ;
Tsunemi, H ;
Yoshita, K ;
Miyata, E ;
Ohtani, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1998, 37 (08) :4627-4631
[4]  
LUMB DH, 1993, P SOC PHOTO-OPT INS, V1736, P138, DOI 10.1117/12.140471
[5]   Measurement of the subpixel structure of AXAF CCD's [J].
Pivovaroff, M ;
Jones, S ;
Bautz, M ;
Kissel, S ;
Prigozhin, G ;
Ricker, G ;
Tsunemi, H ;
Miyata, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) :164-175
[6]  
Townsley LK, 2000, ASTROPHYS J, V534, pL139, DOI 10.1086/312672
[7]   Diagnostics of the CCD using the mesh experiment [J].
Tsunemi, H ;
Hiraga, J ;
Mori, K ;
Yoshita, K ;
Miyata, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) :32-39
[8]   Where are the x-ray event grades formed inside the pixel of the charge-coupled device? The behavior of the primary charge cloud inside the charge-coupled device [J].
Tsunemi, H ;
Hiraga, J ;
Yoshita, K ;
Kitamoto, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1998, 37 (5A) :2734-2739
[9]   New technique of the X-ray efficiency measurement of a charge-coupled device with a subpixel resolution [J].
Tsunemi, H ;
Yoshita, K ;
Kitamoto, S .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1997, 36 (5A) :2906-2911
[10]   0957+561-A, B - TWIN QUASISTELLAR OBJECTS OR GRAVITATIONAL LENS [J].
WALSH, D ;
CARSWELL, RF ;
WEYMANN, RJ .
NATURE, 1979, 279 (5712) :381-384