Optimal electron and combined electron and photon therapy in the phase space of complication-free cure

被引:26
作者
Åsell, M
Hyödynmaa, S
Söderström, S
Brahme, A
机构
[1] Karolinska Inst, Dept Med Radiat Phys, S-17176 Stockholm, Sweden
[2] Tampere Univ Hosp, Dept Radiat Therapy, FIN-33521 Tampere, Finland
关键词
D O I
10.1088/0031-9155/44/1/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The possibility of using intensity-modulated high-energy electrons beams alone or in combination with photon beams to treat tumours located at depths from 5 cm to 25 cm has been investigated. A radiobiologically based optimization algorithm using the probability of complication-free tumour control has been used to calculate the optimal dose distributions. Two different target volumes have been used; one advanced cervical cancer with locally involved lymph nodes and one astrocytoma in the upper brain hemisphere. Treatments with only electron beams and also combinations between electron and photon beams have been investigated. The dependence of the expected treatment outcome on the beam energy and directions was investigated, and to some extent on the number of beam portals. It is shown that the beam direction intervals resulting in a high expected treatment outcome increase with increasing electron energy and also with some electron-photon combinations. For an eccentrically placed, not too deeply situated tumour surrounded by sensitive normal tissue it is shown that the expected treatment outcome can be improved by using electron beams in combination with photon beams compared with using two photon beams, and using two electron beams results in almost as high an expected treatment outcome. The possibility of improving the dose conformity from electron beams by adding photon fields parallel or orthogonal to the electron beams is demonstrated.
引用
收藏
页码:235 / 252
页数:18
相关论文
共 24 条
[1]  
A'gren-Cronqvist A. K., 1995, THESIS STOCKHOLM U
[2]   Specification of dose delivery in radiation therapy - Recommendations by the Nordic Association of Clinical Physics (NACP) [J].
Aaltonen, P ;
Brahme, A ;
Lax, I ;
Levernes, S ;
Naslund, I ;
Reitan, JB ;
Turesson, I .
ACTA ONCOLOGICA, 1997, 36 :1-32
[3]   Optimization of 3D conformal electron beam therapy in inhomogeneous media by concomitant fluence and energy modulation [J].
Asell, M ;
Hyodynmaa, S ;
Gustafsson, A ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2083-2100
[4]  
BRAHME A, 1995, RAD THERAPY PHYSICS, P209
[5]   PHOTON-BEAM ENERGY DEPOSITION KERNELS FOR INVERSE RADIOTHERAPY PLANNING [J].
EKLOF, A ;
AHNESJO, A ;
BRAHME, A .
ACTA ONCOLOGICA, 1990, 29 (04) :447-454
[6]   A GENERALIZED PENCIL BEAM ALGORITHM FOR OPTIMIZATION OF RADIATION-THERAPY [J].
GUSTAFSSON, A ;
LIND, BK ;
BRAHME, A .
MEDICAL PHYSICS, 1994, 21 (03) :343-357
[7]   NUMERICAL-CALCULATION OF ENERGY DEPOSITION BY BROAD HIGH-ENERGY ELECTRON-BEAMS [J].
HUIZENGA, H ;
STORCHI, PRM .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (10) :1371-1396
[8]   NUMERICAL-CALCULATION OF ENERGY DEPOSITION BY HIGH-ENERGY ELECTRON-BEAMS .3. 3-DIMENSIONAL HETEROGENEOUS MEDIA [J].
JANSSEN, JJ ;
RIEDEMAN, DEJ ;
MORAWSKAKACZYNSKA, M ;
STORCHI, PRM ;
HUIZENGA, H .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) :1351-1366
[9]   TUMOR AND NORMAL TISSUE RESPONSES TO FRACTIONATED NONUNIFORM DOSE DELIVERY [J].
KALLMAN, P ;
AGREN, A ;
BRAHME, A .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1992, 62 (02) :249-262
[10]   Exploration of new treatment modalities offered by high energy (up to 50 MeV) electrons and photons [J].
Karlsson, M ;
Zackrisson, B .
RADIOTHERAPY AND ONCOLOGY, 1997, 43 (03) :303-309