Performance of a new schottky CdTe detector for hard X-ray spectroscopy

被引:131
作者
Matsumoto, C
Takahashi, T
Takizawa, K
Ohno, R
Ozaki, T
Mori, K
机构
[1] Inst Space & Astronaut Sci, Sagamihara, Kanagawa 2298510, Japan
[2] Univ Tokyo, Dept Astron, Tokyo 1130033, Japan
[3] Japan Energy Corp, ACROTEC, Toda, Saitama 3358502, Japan
[4] CLEAR PULSE Co Ltd, Tokyo 1430024, Japan
关键词
D O I
10.1109/23.682421
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report a significant improvement of spectral properties of a cadmium telluride (CdTe) detector. This was accomplished via the use of a high quality CdTe crystal, where high Schottky barrier for the holes oil a CdTe surface was formed by using a low work-function metal, indium. With a 2x2 mm(2) detector at a thickness of 0.5 mm, the leakage current is measured to be 0.7 nA at room temperature (20 degrees C) and below 1 pA at -70 degrees C for 400 V bias voltage. The low leakage current allows us to operate the detector at a higher bias voltage than for previous CdTe detectors. The energy resolution we achieved at room temperature is 1.1-2.5 keV FWHM from the energy range of 2 keV to 150 keV at 20 degrees C without any charge-loss correction electronics. At -70 degrees C we obtained all energy resolution of 1.0 keV FWHM at 122 keV and 2.1 keV FWHM at 662 keV.
引用
收藏
页码:428 / 432
页数:5
相关论文
共 12 条
[1]   Room temperature semiconductor detectors for safeguards measurements [J].
Arlt, R ;
Rundquist, DE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :455-461
[2]   TIME-DEPENDENT POLARIZATION OF CDTE GAMMA-RAY DETECTORS [J].
BELL, RO ;
ENTINE, G ;
SERREZE, HB .
NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01) :267-271
[3]   A 90 ELEMENT CDTE ARRAY DETECTOR [J].
IWASE, Y ;
FUNAKI, M ;
ONOZUKA, A ;
OHMORI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :628-632
[4]  
IWASE Y, 1993, MATER RES SOC SYMP P, V302, P225, DOI 10.1557/PROC-302-225
[5]   POLARIZATION PHENOMENA IN CDTE NUCLEAR RADIATION DETECTORS [J].
MALM, HL ;
MARTINI, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) :322-330
[6]  
MATZ R, IN PRESS NUCL INST A
[7]  
OHNO R, 1996, IONIZING RAD, V22, P9
[8]   Thermal treatment of CdTe surfaces for radiation detectors [J].
Ozaki, T ;
Iwase, Y ;
Takamura, H ;
Ohmori, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) :141-144
[9]   HIGH-RESOLUTION GAMMA-RAY SPECTROSCOPY WITH CDTE DETECTOR SYSTEMS [J].
RICHTER, M ;
SIFFERT, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) :529-537
[10]   ADVANCES IN CDTE GAMMA-RAY DETECTORS [J].
SERREZE, HB ;
ENTINE, G ;
BELL, RO ;
WALD, FV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) :404-407