Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance

被引:513
作者
Bellenger, NG [1 ]
Davies, LC [1 ]
Francis, JM [1 ]
Coats, AJS [1 ]
Pennell, DJ [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Cardiovasc MR Unit, Royal Brompton Hosp, Natl Heart & Lung Inst, London SW7 2AZ, England
关键词
heart failure; magnetic resonance imaging; remodeling; reproducibility; sample size;
D O I
10.3109/10976640009148691
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fast breathhold cardiovascular magnetic resonance (CMR) has become a reference standard for the measurement of cardiac volumes, functions, and mass. The implications of this for sample sizes for remodeling studies in heart failure (HF) have not been elucidated. We determined the reproducibility of CMR in HF and calculated the sample size requirements and compared them with published values for echocardiography. Breathhold gradient echo cines of the left ventricle were acquired in 20 patients with HF and 20 normal subjects. Sample size values were calculated from the interstudy standard deviation of the difference. The percentage variability of the measured parameters ib our group of intraobserver (2.0-7.4%), interobserver (3.3-7.7%), and interstudy (2.5-4.8%) measurements was slightly larger than for our normal group (1.6-6.6%, 1.6-7.3%, and 2.0-7.3%, respectively) but remained comparable with previous studies in normal subjects. The calculated sample sizes in patients with HF for CMR to detect a 10-ml change in end-diastolic volume (n = 12) and end-systolic volume (n = 10), a 3% change in ejection fraction (n = 15), and a 10-g change in mass was (n = 9) were substantially smaller than recently published values for two-dimensional echocardiography (reduction of 81-97%). Breathhold CMR is a fast comprehensive technique for the assessment of cardiac volumes, function, and mass in HF that is accurate but also highly reproducible. This allows a considerable reduction in the patient numbers required to prove a hypothesis in research studies, which suggests a potential for important research cost savings.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 35 条
  • [21] LONGMORE DB, 1985, LANCET, V1, P1360
  • [22] Normal human right and left ventricular mass, systolic function, and gender differences by cine magnetic resonance imaging
    Lorenz, CH
    Walker, ES
    Morgan, VL
    Klein, SS
    Graham, TP
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 1999, 1 (01) : 7 - 21
  • [23] ASSESSMENT OF LEFT-VENTRICULAR VOLUMES BY MAGNETIC-RESONANCE IN COMPARISON WITH RADIONUCLIDE ANGIOGRAPHY, CONTRAST ANGIOGRAPHY AND ECHOCARDIOGRAPHY
    MOGELVANG, J
    STOKHOLM, KH
    SAUNAMAKI, K
    REIMER, A
    STUBGAARD, M
    THOMSEN, C
    FRITZHANSEN, P
    HENRIKSEN, O
    [J]. EUROPEAN HEART JOURNAL, 1992, 13 (12) : 1677 - 1683
  • [24] RISK STRATIFICATION AND SURVIVAL AFTER MYOCARDIAL-INFARCTION
    MOSS, AJ
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (06) : 331 - 336
  • [25] Otterstad JE, 1997, EUR HEART J, V18, P507
  • [26] LEFT-VENTRICULAR MEASUREMENTS WITH CINE AND SPIN-ECHO MR IMAGING - A STUDY OF REPRODUCIBILITY WITH VARIANCE COMPONENT ANALYSIS
    PATTYNAMA, PMT
    LAMB, HJ
    VANDERVELDE, EA
    VANDERWALL, EE
    DEROOS, A
    [J]. RADIOLOGY, 1993, 187 (01) : 261 - 268
  • [27] LEFT-VENTRICULAR VOLUMES MEASURED BY MR IMAGING
    REHR, RB
    MALLOY, CR
    FILIPCHUK, NG
    PESHOCK, RM
    [J]. RADIOLOGY, 1985, 156 (03) : 717 - 719
  • [28] EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING
    SAKUMA, H
    FUJITA, N
    FOO, TKF
    CAPUTO, GR
    NELSON, SJ
    HARTIALA, J
    SHIMAKAWA, A
    HIGGINS, CB
    [J]. RADIOLOGY, 1993, 188 (02) : 377 - 380
  • [29] MEASUREMENT OF RIGHT AND LEFT-VENTRICULAR VOLUMES IN HEALTHY-INDIVIDUALS WITH CINE MR IMAGING
    SECHTEM, U
    PFLUGFELDER, PW
    GOULD, RG
    CASSIDY, MM
    HIGGINS, CB
    [J]. RADIOLOGY, 1987, 163 (03) : 697 - 702
  • [30] INTERSTUDY REPRODUCIBILITY OF DIMENSIONAL AND FUNCTIONAL MEASUREMENTS BETWEEN CINE MAGNETIC-RESONANCE STUDIES IN THE MORPHOLOGICALLY ABNORMAL LEFT-VENTRICLE
    SEMELKA, RC
    TOMEI, E
    WAGNER, S
    MAYO, J
    CAPUTO, G
    OSULLIVAN, M
    PARMLEY, WW
    CHATTERJEE, K
    WOLFE, C
    HIGGINS, CB
    [J]. AMERICAN HEART JOURNAL, 1990, 119 (06) : 1367 - 1373