Temporal sampling requirements for the tracer kinetics modeling of breast disease

被引:219
作者
Henderson, E [1 ]
Rutt, BK [1 ]
Lee, TY [1 ]
机构
[1] John P Robarts Res Inst, Lawson Family Imaging Res Labs, London, ON N6A 5K8, Canada
关键词
temporal sampling; tracer kinetics model; breast; contrast agent;
D O I
10.1016/S0730-725X(98)00130-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The physiological parameters measured in the tracer kinetics modeling of data from a dynamic contrast-enhanced magnetic resonance (MR) breast exam (blood flow-extraction fraction product [FE], volume of the extracellular extravascular space [V-e], and blood volume [V-b]) may enable non-invasive diagnosis of breast cancer. One of the factors that compromises the accuracy and precision of the parameter estimates, and therefore their diagnostic potential, is the temporal resolution of the MR scans used to measure contrast agent (gadolinium-diethylenetriamine pentaacetic acid [Gd-DTPA]) concentration in an artery (arterial input function [AIF]) and in the tissue (tissue residue function [TRF]), Using computer simulations, we have examined, for several AIF widths, the errors introduced into estimates of tracer kinetic parameters in breast tissue due to insufficient temporal sampling. Temporal sampling errors can be viewed as uncertainties and biases in the parameter estimates introduced by the uncertainty in the relative alignments of the AIF, TRF, and sampling grid. These effects arise from the model's inherent sensitivity to error in either the AIF or TRF, which is dependent on the values of the tracer kinetic parameters and increases with AIF width. Based on the results of the simulations, to ensure that the error in FE and V-e will be under 10% of their true values, we recommend a rapid bolus injection of contrast agent (similar to 10 s), that the AIF be sampled every second, and that the TRF be sampled every 16 s or less. An accurate measurement of V-b requires that the TRF be sampled at least every 4 s. The results of these investigations can be used to set minimum dynamic imaging rates for tracer kinetics modeling of the breast. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1057 / 1073
页数:17
相关论文
共 47 条
  • [1] Arterial input functions from MR phase imaging
    Akbudak, E
    Conturo, TE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) : 809 - 815
  • [2] Approximation of arterial input curve data in MRI estimation of cerebral blood-tumor-barrier leakage: Comparison between Gd-DTPA and Tc-99m-DTPA input curves
    Andersen, C
    Taagehoj, JF
    Muhler, A
    Rehling, M
    [J]. MAGNETIC RESONANCE IMAGING, 1996, 14 (03) : 235 - 241
  • [3] MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE
    BOETES, C
    BARENTSZ, JO
    MUS, RD
    VANDERSLUIS, RF
    VANERNING, LJTO
    HENDRIKS, JHCL
    HOLLAND, R
    RUYS, SHJ
    [J]. RADIOLOGY, 1994, 193 (03) : 777 - 781
  • [4] Assessing tumor angiogenesis using macromolecular MR imaging contrast media
    Brasch, R
    Pham, C
    Shames, D
    Roberts, T
    vanDijke, K
    vanBruggen, N
    Mann, J
    Ostrowitzki, S
    Melnyk, O
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 68 - 74
  • [5] Breast lesions: Correlation of contrast medium enhancement patterns on MR images with histopathologic findings and tumor angiogenesis
    Buadu, LD
    Murakami, J
    Murayama, S
    Hashiguchi, N
    Sakai, S
    Masuda, K
    Toyoshima, S
    Kuroki, S
    Ohno, S
    [J]. RADIOLOGY, 1996, 200 (03) : 639 - 649
  • [6] QUANTITATIVE-ANALYSIS OF MULTISLICE GD-DTPA ENHANCED DYNAMIC MR-IMAGES USING AN AUTOMATED SIMPLEX MINIMIZATION PROCEDURE
    BUCKLEY, DL
    KERSLAKE, RW
    BLACKBAND, SJ
    HORSMAN, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (05) : 646 - 651
  • [7] BUDINGER TF, 1985, CIRCULATION, V72, P53
  • [8] Pharmacokinetic analysis of Gd-DTPA enhancement in dynamic three-dimensional MRI of breast lesions
    denBoer, JA
    Hoenderop, RKKM
    Smink, J
    Dornseiffen, G
    Koch, PWAA
    Mulder, JH
    Slump, CH
    Volker, EDP
    deVos, RAI
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (04): : 702 - 715
  • [9] EDMINSTER WB, 1997, 5 ANN M INT SOC MAGN, V2, P849