Optimization of gadolinium-enhanced magnetic resonance angiography using an automated bolus-detection algorithm (MR SmartPrep) - Original investigation

被引:44
作者
Ho, VB [1 ]
Foo, TKF
机构
[1] Uniformed Serv Univ Hlth Sci, Dept Radiol, MR Res Div, Bethesda, MD 20814 USA
[2] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
[3] GE Co, Med Syst, Appl Sci Lab, Bethesda, MD USA
关键词
magnetic resonance : vascular studies; contrast enhancement; technology; gadolinium;
D O I
10.1097/00004424-199809000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gadolinium (Gd)-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) is a quick method for performing noninvasive diagnostic angiography, A major technical obstacle to the successful implementation of this technique, however, is the proper coordination of the data acquisition with the contrast bolus, In this article, the use of an automated bolus-detection algorithm (MR SmartPrep), which triggers the initiation of data acquisition for Gd-enhanced 3D MRA is reviewed. Potential applications of this evolving technique are illustrated.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 25 条
[1]   Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector [J].
Earls, JP ;
Rofsky, NM ;
DeCorato, DR ;
Krinsky, GA ;
Weinreb, JC .
RADIOLOGY, 1996, 201 (03) :705-710
[2]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[3]  
FOO TKF, 1998, P 6 M INT SOC MAGN R, P67
[4]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[5]  
ISODA H, IN PRESS AJNR
[6]   Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography [J].
Kim, JK ;
Farb, RI ;
Wright, GA .
RADIOLOGY, 1998, 206 (01) :283-289
[7]  
KO KYJ, 1998, RADIOLOGY, V206, P683
[8]   Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography [J].
Kopka, L ;
Vosshenrich, R ;
Rodenwaldt, J ;
Grabbe, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) :345-348
[9]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[10]   Gadolinium-enhanced three-dimensional MR angiography of acquired arch vessel disease [J].
Krinsky, G ;
Rofsky, N ;
Flyer, M ;
Giangola, G ;
Maya, M ;
DeCoroto, D ;
Earls, J ;
Weinreb, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) :981-987