Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopy

被引:73
作者
Uo, M
Watari, F
Yokoyama, A
Matsuno, H
Kawasaki, T
机构
[1] Hokkaido Univ, Sch Dent, Dept Dent Mat & Engn, Kita Ku, Sapporo, Hokkaido 060, Japan
[2] Hokkaido Univ, Sch Dent, Dept Removable Prosthet Dent, Kita Ku, Sapporo, Hokkaido 060, Japan
关键词
X-ray scanning analytical microscopy; toxicity; dissolution; implant; elemental mapping;
D O I
10.1016/S0142-9612(98)00224-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recently developed X-ray scanning analytical microscope (XSAM) was applied for the analysis of the soft tissue of rat in which Ni was implanted and serious inflammation occurred. Our aim is to investigate the relationship between tissue response and elemental distributions. The XSAM observation was conducted in air without pretreatment and staining of samples. Mapping images of P, S, Ca, Fe and Ni, which were the elements with low concentration in soft tissue, were obtained from the soft tissue blocks of rat where Ni was implanted. S mapping image showed the localization of S in muscle and in hairs. Ca mapping image showed the localization of Ca in muscle and hair roots. Fe distribution was also observed and the localized area was consistent with the hemorrhagic area. The Ni dissolution area was clearly detected around the Ni implant. Comparison with the histological observation showed that the Ni dispersed area was consistent with the inflammatory area and the degree of tissue damage was closely related to the dissolved Ni concentration. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:747 / 755
页数:9
相关论文
共 13 条
[1]  
Al-Waheidi E M, 1995, Quintessence Int, V26, P385
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
[Anonymous], 1995, P 3 INT S STRUCT FUN
[4]   ALLERGIC REACTION TO ORTHODONTIC WIRE - REPORT OF CASE [J].
DUNLAP, CL ;
VINCENT, SK ;
BARKER, BF .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1989, 118 (04) :449-450
[5]   INTENSITY OF X-RAY MICROBEAM FORMED BY A HOLLOW GLASS PIPE [J].
FURUTA, K ;
NAKAYAMA, Y ;
SHOJI, M ;
NAKANO, H ;
HOSOKAWA, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03) :828-829
[6]   THEORETICAL CONSIDERATION OF INTENSITY OF AN X-RAY MICROBEAM FORMED BY A HOLLOW GLASS PIPE [J].
FURUTA, K ;
NAKAYAMA, Y ;
SHOJI, M ;
KAIGAWA, R ;
HANAMOTO, K ;
NAKANO, H ;
HOSOKAWA, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01) :135-142
[7]  
Hosokawa Y, 1997, X-RAY SPECTROM, V26, P380
[8]  
*JAP BIOCH SOC, 1979, BIOCH DAT, V294, P1649
[9]  
LAING PATRICK G., 1967, J BIOMED MAT RES, V1, P135, DOI 10.1002/jbm.820010113
[10]  
NAKAZAWA H, 1990, MICROSCOPY BIOL MED, P81