THEORETICAL CONSIDERATION OF INTENSITY OF AN X-RAY MICROBEAM FORMED BY A HOLLOW GLASS PIPE

被引:34
作者
FURUTA, K [1 ]
NAKAYAMA, Y [1 ]
SHOJI, M [1 ]
KAIGAWA, R [1 ]
HANAMOTO, K [1 ]
NAKANO, H [1 ]
HOSOKAWA, Y [1 ]
机构
[1] HORIBA LTD,DIV RES & DEV,MINAMI KU,KYOTO 601,JAPAN
关键词
D O I
10.1063/1.1144427
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Intensities of x-ray microbeams formed by the 250-mm-long hollow glass pipes of inner diameters of 27.4, 23.0, and 18.8 mum have been theoretically investigated, by taking account of the slope distribution of microprojections (surface roughness) on the pipe inner wall, using the Monte Carlo method. The intensities for all the pipes calculated on the supposition that each pipe inner wall is perfect (i.e., zero rms of the slope distribution) have been much greater than the experimental values in the x-ray energy region from 6.93 to 19.6 keV. Assuming the slope rms from 2.5 X 10(-4) rad to 3.3 X 10(-3) rad, the calculated results have agreed with the experimental values. Discussions on the results for all the pipes are given in relation to the x-ray anomalous dispersion, the penetration of x rays, the intensity distribution on the x-ray sources used, undulation of the pipes, and the presence of microdust in the pipes.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 22 条
[1]   A SOFT-X-RAY MICROPROBE USING AN AXISYMMETRICAL TANDEM TOROIDAL MIRROR [J].
AOKI, S ;
YAMAJI, H .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1987, 26 (10) :1768-1771
[2]   X-RAY WAVELENGTHS [J].
BEARDEN, JA .
REVIEWS OF MODERN PHYSICS, 1967, 39 (01) :78-&
[3]   MEASUREMENT OF RMS ROUGHNESS, AUTOCOVARIANCE FUNCTION AND OTHER STATISTICAL PROPERTIES OF OPTICAL SURFACES USING A FECO SCANNING INTERFEROMETER [J].
BENNETT, JM .
APPLIED OPTICS, 1976, 15 (11) :2705-2721
[4]  
CARPENTER DA, 1991, ADV X RAY ANAL, V34, P217
[5]   IMPROVED LABORATORY X-RAY SOURCE FOR MICROFLUORESCENCE ANALYSIS [J].
CARPENTER, DA .
X-RAY SPECTROMETRY, 1989, 18 (06) :253-257
[6]  
Compton A. H., 1935, XRAYS THEORY EXPT
[7]   A 200 MU-M X-RAY MICROBEAM SPECTROMETER [J].
ENGSTROM, P ;
LARSSON, S ;
RINDBY, A ;
STOCKLASSA, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 36 (02) :222-226
[8]   INTENSITY OF X-RAY MICROBEAM FORMED BY A HOLLOW GLASS PIPE [J].
FURUTA, K ;
NAKAYAMA, Y ;
SHOJI, M ;
NAKANO, H ;
HOSOKAWA, Y .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (03) :828-829
[9]   MULTIPLE REFLECTION FROM SURFACE X-RAY OPTICS [J].
KUMAKHOV, MA ;
KOMAROV, FF .
PHYSICS REPORTS-REVIEW SECTION OF PHYSICS LETTERS, 1990, 191 (05) :289-350
[10]   X-RAY LIGHT PIPES [J].
MOSHER, D ;
STEPHANAKIS, SJ .
APPLIED PHYSICS LETTERS, 1976, 29 (02) :105-107