High-resolution computer simulation of the dynamics of isoelectric focusing of proteins

被引:51
作者
Thormann, W
Huang, TM
Pawliszyn, J
Mosher, RA
机构
[1] Univ Bern, Dept Clin Pharmacol, CH-3010 Bern, Switzerland
[2] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[3] RAM Software Solut, Tucson, AZ USA
关键词
capillary isoelectric focusing; hemoglobin;
D O I
10.1002/elps.200305749
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A dynamic electrophoresis simulator that accepts 150 components and voltage gradients employed in the laboratory was used to provide a detailed description of the focusing process of proteins under conditions that were hitherto inaccessible. High-resolution focusing data of four hemoglobin variants in a convection-free medium are presented for pH 3-10 and pH 5-8 gradients formed with 20 and 40 carrier ampholytes/pH unit, respectively. With 300 V/cm, focusing is shown to occur within 5-10 min, whereas at 600 V/cm separation is predicted to be complete between 2.5 and 5 min. The time interval required for focusing of proteins is demonstrated to be dependent on the input protein charge data and, however less, on the properties of the carrier ampholytes. The simulation data reveal that the number of transient protein boundaries migrating from the two ends of the column towards the focusing positions is equal to the number of sample components. Each protein is being focused via the well-known double-peak approach to equilibrium, a process that is also characteristic for focusing of the carrier ampholytes. The predicted focusing dynamics for the hemoglobin variants in pH 3-10 and pH 5-8 gradients are shown to qualitatively agree well with experimental data obtained by whole-column optical imaging.
引用
收藏
页码:324 / 337
页数:14
相关论文
共 52 条
[1]  
ALMGREN M, 1971, CHEM SCRIPTA, V1, P69
[2]   SPATIAL-SCANNING LASER FLUORESCENCE DETECTION FOR CAPILLARY ELECTROPHORESIS [J].
BEALE, SC ;
SUDMEIER, SJ .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3367-3371
[3]   RAPID, MULTISAMPLE ISOELECTRIC FOCUSING IN SUCROSE DENSITY GRADIENTS USING CONVENTIONAL POLYACRYLAMIDE ELECTROPHORESIS EQUIPMENT - 2-PEAK TRANSIENT IN APPROACH-TO-EQUILIBRIUM [J].
BEHNKE, JN ;
DAGHER, SM ;
MASSEY, TH ;
DEAL, WC .
ANALYTICAL BIOCHEMISTRY, 1975, 69 (01) :1-9
[4]   Recycling isoelectric focusing and isotachophoresis [J].
Bier, M .
ELECTROPHORESIS, 1998, 19 (07) :1057-1063
[5]   ANALYTICAL SCANNING ISOELECTROFOCUSING [J].
CATSIMPOOLAS, N .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1973, 209 (JUN15) :65-79
[6]   SCANNING GEL ISOELECTROFOCUSING OF PROTEINS [J].
CATSIMPOOLAS, N ;
WANG, J .
ANALYTICAL BIOCHEMISTRY, 1971, 39 (01) :141-+
[7]  
CATSIMPOOLAS N, 1975, PROGR ISOELECTRIC FO, P77
[8]   Studies in the physical chemistry of the proteins XIV The amphoteric properties of hemoglobin [J].
Cohn, EJ ;
Green, AA ;
Blanchard, MH .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1937, 59 :509-517
[9]   ROLE OF CHARGE SUPPRESSION AND IONIC-STRENGTH IN FREE ZONE ELECTROPHORESIS OF PROTEINS [J].
COMPTON, BJ ;
OGRADY, EA .
ANALYTICAL CHEMISTRY, 1991, 63 (22) :2597-2602
[10]   ELECTROPHORETIC MOBILITY MODELING OF PROTEINS IN FREE ZONE CAPILLARY ELECTROPHORESIS AND ITS APPLICATION TO MONOCLONAL-ANTIBODY MICROHETEROGENEITY ANALYSIS [J].
COMPTON, BJ .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :357-366