Recent trends in potentiometric sensor arrays-A review

被引:173
作者
Bratov, A. [1 ]
Abramova, N. [1 ]
Ipatov, A. [1 ]
机构
[1] CSIC, IMB, CNM, Barcelona 08193, Spain
关键词
Potentiometric sensors; Sensor array; Electronic tongue; Multicomponent analysis; INTEGRATED MULTISENSOR CHIP; SELECTIVE ELECTRODE ARRAYS; FIELD-EFFECT TRANSISTORS; TOTAL ANALYSIS SYSTEMS; CELL-BASED BIOSENSORS; HEAVY-METAL ANALYSIS; OF-THE-ART; CHEMICAL SENSORS; ELECTROCHEMICAL SENSORS; MULTICOMPONENT ANALYSIS;
D O I
10.1016/j.aca.2010.08.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays there exists a large variety of ion sensors based on polymeric or solid-state membranes that can be used in a sensor array format in many analytical applications. This review aims at providing a critical overview of the distinct approaches that were developed to build and use potentiometric sensor arrays based on different transduction principles, such as classical ion-selective electrodes (ISEs) with polymer or solid-state membranes, solid-contact electrodes (SCE) including coated wire electrodes (CWE), ion-sensitive field-effect transistors (ISFETs) and light addressable potentiometric sensors (LAPS) Analysing latest publications on potentiometric sensor arrays development and applications certain problems are outlined and trends are discussed (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:149 / 159
页数:11
相关论文
共 193 条
[1]   The influence of CO2 on ISFETs with polymer membranes and characterization of a carbonate ion sensor [J].
Abramova, Natalia ;
Levichev, Sergey ;
Bratov, Andrey .
TALANTA, 2010, 81 (4-5) :1750-1754
[2]   Photocurable Polymers for Ion Selective Field Effect Transistors. 20 Years of Applications [J].
Abramova, Natalia ;
Bratov, Andrei .
SENSORS, 2009, 9 (09) :7097-7110
[3]   Integrated multi-sensor chip with photocured polymer membranes containing copolymerised plasticizer for direct pH, potassium, sodium and chloride ions determination in blood serum [J].
Abramova, Natalia ;
Ipatov, Andrey ;
Levichev, Sergey ;
Bratov, Andrey .
TALANTA, 2009, 79 (04) :984-989
[4]   Development of multichannel artificial lipid-polymer membrane sensor for phytomedicine application [J].
Ahmad, Mohd Noor ;
Ismail, Zhari ;
Chew, Oon-Sim ;
Islam, A. K. M. Shafiqul ;
Shakaff, Ali Yeon Md .
SENSORS, 2006, 6 (10) :1333-1344
[5]  
Alexander PW, 1998, ELECTROANAL, V10, P707, DOI 10.1002/(SICI)1521-4109(199808)10:10<707::AID-ELAN707>3.3.CO
[6]  
2-M
[7]  
Alexander PW, 1996, FIELD ANAL CHEM TECH, V1, P31
[8]   A Novel Thin-Film Copper Array Based on an Organic/Inorganic Sensor Hybrid: Microfabrication, Potentiometric Characterization, and Flow-Injection Analysis Application [J].
Arida, Hassan ;
Turek, Monika ;
Rolka, David ;
Schoening, Michael J. .
ELECTROANALYSIS, 2009, 21 (10) :1145-1151
[9]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[10]   Microelectronic sensor system for microphysiological application on living cells [J].
Baumann, WH ;
Lehmann, M ;
Schwinde, A ;
Ehret, R ;
Brischwein, M ;
Wolf, B .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (01) :77-89