Effect of mixing modes on chemiluminescent detection of epinephrine with lucigenin by an FIA system fabricated on a microchip

被引:25
作者
Kamidate, T [1 ]
Kaide, T [1 ]
Tani, H [1 ]
Makino, E [1 ]
Shibata, T [1 ]
机构
[1] Hokkaido Univ, Grad Sch Engn, Sapporo, Hokkaido 0608628, Japan
关键词
D O I
10.2116/analsci.17.951
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The chemiluminescent (CL) detection of epinephrine (EP) with lucigenin (Luc) was performed using a micro flow cell fabricated on a silicon chip. A solution of EP was injected into the Luc carrier stream. The Luc solution containing EP and an alkaline solution were successively poured into the flow cell by a pressure-driven flow system. Two types of flow cells were fabricated for estimating the effect of the mixing modes in the flow cells on the intensity of light emission. In flow cell 1, two streams entered through separate inlet ports and merged to flow adjacently. In flow cell 2, a Luc solution containing EP was split up to 36 partial flows by passage through the nozzles, and was injected into the alkaline solution. The intensity of light emission in flow cell 2 increased markedly compared to that in flow cell 1. The detection limit of 8.0 x 10(-7) M for EP in flow cell 2 was a factor of six-times better than that in flow cell 1. The improvement in the sensitivity for EP could be explained in terms of the distortion of laminar flow in flow cell 2.
引用
收藏
页码:951 / 955
页数:5
相关论文
共 21 条
[1]   Chemiluminescent assay for catecholamines by the generation of hydrogen peroxide in basic solution and the use of isoluminol-microperoxidase [J].
Arakawa, H ;
Kanemitsu, M ;
Maeda, M .
ANALYTICAL SCIENCES, 1999, 15 (12) :1269-1272
[2]   Microstructure for efficient continuous flow mixing [J].
Bessoth, FG ;
deMello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1999, 36 (06) :213-215
[3]   TOWARDS INTEGRATED MICROLIQUID HANDLING SYSTEMS [J].
ELWENSPOEK, M ;
LAMMERINK, TSJ ;
MIYAKE, R ;
FLUITMAN, JHJ .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1994, 4 (04) :227-245
[4]   Microchip capillary electrophoresis using on-line chemiluminescence detection [J].
Hashimoto, M ;
Tsukagoshi, K ;
Nakajima, R ;
Kondo, K ;
Arai, A .
JOURNAL OF CHROMATOGRAPHY A, 2000, 867 (1-2) :271-279
[5]   MICELLE-ENHANCED CHEMI-LUMINESCENCE AND APPLICATION TO THE DETERMINATION OF BIOLOGICAL REDUCTANTS USING LUCIGENIN [J].
HINZE, WL ;
RIEHL, TE ;
SINGH, HN ;
BABA, Y .
ANALYTICAL CHEMISTRY, 1984, 56 (12) :2180-2191
[6]   Microfabricated flow chamber for fluorescence-based chemistries and stopped-flow injection cytometry [J].
Hodder, PS ;
Blankenstein, G ;
Ruzicka, J .
ANALYST, 1997, 122 (09) :883-887
[7]   Quantitative analysis of molecular interaction in a microfluidic channel: The T-sensor [J].
Kamholz, AE ;
Weigl, BH ;
Finlayson, BA ;
Yager, P .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5340-5347
[8]   MICELLE-ENHANCED LUCIGENIN CHEMILUMINESCENCE FOR THE DETERMINATION OF CATECHOLAMINES [J].
KAMIDATE, T ;
YOSHIDA, K ;
KANEYASU, T ;
SEGAWA, T ;
WATANABE, H .
ANALYTICAL SCIENCES, 1990, 6 (05) :645-649
[9]   ENHANCEMENT OF LUCIGENIN CHEMILUMINESCENCE BY PERIODATE-OXIDATION OF ADRENALINE IN CATIONIC SURFACTANT MICELLES [J].
KAMIDATE, T ;
KANEYASU, T ;
SEGAWA, T ;
WATANABE, H .
CHEMISTRY LETTERS, 1991, (10) :1719-1722
[10]   ENHANCED CHEMILUMINESCENCE OF LUCIGENIN WITH EPINEPHRINE IN CATIONIC SURFACTANT MICELLES CONTAINING PERIODATE [J].
KAMIDATE, T ;
ICHIHASHI, H ;
SEGAWA, T ;
WATANABE, H .
JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1995, 10 (01) :55-61