Measured lung dose correction factors for 50 MV photons

被引:9
作者
Blomquist, M [1 ]
Karlsson, M [1 ]
机构
[1] Umea Univ, Dept Radiat Phys, SE-90185 Umea, Sweden
关键词
D O I
10.1088/0031-9155/43/11/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Some clinically relevant measurements of lung tissue/water equivalent interfaces have been performed for a 50 MV therapeutic x-ray beam. The purpose was to investigate the severity of dose perturbation effects in lung tissue and adjacent tissues using an energy well above the common clinical practice in thoracic irradiations. The phantoms were constructed of solid water, PMMA and white polystyrene as soft tissue (water) equivalents, and cork was used as the lung tissue equivalent. Measurements were performed using radiographic film and a cylindrical ionization chamber. The results show that the degradation of the 20/80% beam penumbra in the lung region is severe, up to 2.5 times the penumbra in water for a 10 cm thick lung with a density of 0.30 x 10(3) kg m(-3). The lack of electronic equilibrium in the low-density region can cause underdosage at the lung/tumour interface of up to 30% of maximum target dose, and the build-up depth to 95% of target dose in unit density tissue behind the lung may be as large as 22 mm. It is also shown that these figures strongly depend on patient anatomy and beam size and why a careful calculation of the individual dose distribution is needed for optimal choice of photon beam energy in thoracic treatments.
引用
收藏
页码:3225 / 3234
页数:10
相关论文
共 18 条
[1]   PITFALLS IN THE USE OF HIGH-ENERGY X-RAYS TO TREAT TUMORS IN THE LUNG [J].
EKSTRAND, KE ;
BARNES, WH .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (01) :249-252
[2]  
IAEA (International Atomic Energy Agency), 1997, IAEA TECHN REP SER, V381
[3]   PHOTON-BEAM CHARACTERISTICS ON THE MM50 RACETRACK MICROTRON AND A NEW APPROACH FOR BEAM QUALITY DETERMINATION [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1993, 20 (01) :143-149
[4]   THE INFLUENCE OF AIR CAVITIES ON INTERFACE DOSES FOR PHOTON BEAMS [J].
KLEIN, EE ;
CHIN, LM ;
RICE, RK ;
MIJNHEER, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02) :419-427
[5]   LIMITATIONS OF A PENCIL BEAM APPROACH TO PHOTON DOSE CALCULATIONS IN LUNG-TISSUE [J].
KNOOS, T ;
AHNESJO, A ;
NILSSON, P ;
WEBER, L .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09) :1411-1420
[6]   CHANGES IN THE DOSE-PROFILE OF A 10-MV X-RAY-BEAM WITHIN AND BEYOND LOW-DENSITY MATERIAL [J].
KORNELSEN, RO ;
YOUNG, MEJ .
MEDICAL PHYSICS, 1982, 9 (01) :114-116
[7]   LUNG DOSE CORRECTIONS FOR 6-MV AND 15-MV X-RAYS [J].
MACKIE, TR ;
ELKHATIB, E ;
BATTISTA, J ;
SCRIMGER, J ;
VANDYK, J ;
CUNNINGHAM, JR .
MEDICAL PHYSICS, 1985, 12 (03) :327-332
[8]   EFFECTS OF IONIZATION-CHAMBER CONSTRUCTION ON DOSE MEASUREMENTS IN A HETEROGENEITY [J].
MAUCERI, T ;
KASE, K .
MEDICAL PHYSICS, 1987, 14 (04) :653-656
[9]   A HETEROGENEITY MODEL FOR PHOTON BEAMS INCORPORATING ELECTRON-TRANSPORT [J].
PETTI, PL ;
RICE, RK ;
MIJNHEER, BJ ;
CHIN, LM ;
BJARNGARD, BE .
MEDICAL PHYSICS, 1987, 14 (03) :349-354
[10]   BENCHMARK MEASUREMENTS FOR LUNG DOSE CORRECTIONS FOR X-RAY-BEAMS [J].
RICE, RK ;
MIJNHEER, BJ ;
CHIN, LM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (02) :399-409