Controlling gray level variation in Contrast Enhanced Digital Mammography: design of a calibration procedure

被引:4
作者
Jeunehomme, F [1 ]
Iordache, R [1 ]
Muller, S [1 ]
Mawdsley, G [1 ]
Yaffe, M [1 ]
机构
[1] GE Med Syst, Buc, France
来源
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2003年 / 5030卷
关键词
contrast enhanced digital mammography; breast angiography; iodine-based contrast agent; X-ray imaging; flat panel detector;
D O I
10.1117/12.480485
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ideally, the gray level changes in a Contrast-Enhanced Digital Mammography (CEDM) sequence reflect the uptake and wash-out of contrast medium in the breast. While insignificant in standard mammography, gray level variations with time caused both by patient and system related factors, have been observed in clinical CEDM sequences. We have acquired phantom image series on digital mammography systems using a Mo/Cu anode-filter combination and a tube voltage between 45 and 49 kVp, in order to derive a model for gray level change with time as a function of system parameters. The gray level variation exhibits a fair degree of inter-series repeatability, and-strongly depends on the dose received by the detector and. timing of the image acquisition series. Moreover, for tissue-equivalent compositions, the relative gray level change with respect to the first image does not depend on the composition. We designed a calibration procedure that can be used-to compensate for the tiny system-dependent signal variation that has been observed. A global reduction of 80-93% of the variation has been demonstrated in sequences acquired on a breast shaped phantom. Local improvement is effective across the whole field of view. When imaging iodine inserts (0.5-2 mg/cm(2) concentration), the calibration increases the constancy with time of iodine signal on subtracted sequences by a factor of 4 (median value).
引用
收藏
页码:338 / 348
页数:11
相关论文
共 14 条
[1]   BREAST-LESIONS EXAMINED BY DIGITAL ANGIOGRAPHY - WORK IN PROGRESS [J].
ACKERMAN, LV ;
WATT, AC ;
SHETTY, P ;
FLYNN, MJ ;
BURKE, M ;
KAMBOURIS, A ;
FINE, G ;
WILDERMAN, S .
RADIOLOGY, 1985, 155 (01) :65-68
[2]   COMPUTED TOMOGRAPHIC MAMMOGRAPHY USING A CONVENTIONAL BODY SCANNER [J].
CHANG, CHJ ;
NESBIT, DE ;
FISHER, DR ;
FRITZ, SL ;
DWYER, SJ ;
TEMPLETON, AW ;
LIN, F ;
JEWELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (03) :553-558
[3]   Contrast-enhanced CT: Value for diagnosing local breast cancer recurrence after conservative treatment [J].
Hagay, C ;
Cherel, PJP ;
deMaulmont, CE ;
Plantet, MM ;
Gilles, R ;
Floiras, JLG ;
Garbay, JR ;
Pallud, CM .
RADIOLOGY, 1996, 200 (03) :631-638
[4]   MR IMAGING OF THE BREAST WITH GD-DTPA - USE AND LIMITATIONS [J].
HEYWANG, SH ;
WOLF, A ;
PRUSS, E ;
HILBERTZ, T ;
EIERMANN, W ;
PERMANETTER, W .
RADIOLOGY, 1989, 171 (01) :95-103
[5]  
HEYWANGKOBRUNNE.S, 1986, CONTRAST ENHANCED MR
[6]   Dynamic X-ray imaging system based on an amorphous silicon thin-film array [J].
Jung, N ;
Alving, PL ;
Busse, F ;
Conrads, N ;
Meulenbrugge, HM ;
Rutten, W ;
Schiebel, U ;
Weibrecht, M ;
Wieczorek, H .
PHYSICS OF MEDICAL IMAGING, 1998, 3336 :396-407
[7]   MR IMAGING OF THE BREAST - FAST IMAGING SEQUENCES WITH AND WITHOUT GD-DTPA - PRELIMINARY-OBSERVATIONS [J].
KAISER, WA ;
ZEITLER, E .
RADIOLOGY, 1989, 170 (03) :681-686
[8]  
MARX C, 2002, P SPIE
[9]  
Muller J, 1999, RELIG LIT, V31, P1
[10]   MR imaging of the breast for the detection, diagnosis, and staging of breast cancer [J].
Orel, SG ;
Schnall, MD .
RADIOLOGY, 2001, 220 (01) :13-30