Ultrasonic standing wave chambers with acoustic pathlengths of 1.1 and 0.62 mm have been constructed. The chambers were driven at frequencies over the range 0.66-12.2 MHz. The behaviour of 2 mu m diameter latex microparticles and 5 mu m diameter yeast in the chambers has been elucidated. One (flow) chamber had a downstream laminar flow expansion section to facilitate observation of concentrated particle bands formed in the ultrasonic field. A second (microscopy) chamber allowed direct observation of band formation in the field and their characterisation by confocal scanning laser microscopy. Clear band formation occurs when the chamber pathlength is a multiple of half wavelengths at the driving frequency, so that the chamber rather than the transducer resonance has the most influence on band formation in this system. Band formation occurred in half-wavelength steps from a position one quarter of a wavelength off the transducer to a band at a similar distance from the reflector. Ordered band formation was preserved by the laminar flow in the expansion chamber, although bands that formed very close to the wall were dissipated downstream. The microscopy chamber provided evidence of significant lateral particle concentration within bands in the pressure nodal planes. The approaches described will be applicable to the manipulation of smaller particles in narrower chambers at higher ultrasonic frequencies. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:925 / 931
页数:7
相关论文
共 14 条
[1]  
APFEL RE, 1990, FORTSCH AKUST DAGA 9, P19
[2]   A NOVEL ULTRASONIC RESONANCE FIELD DEVICE FOR THE RETENTION OF ANIMAL-CELLS [J].
DOBLHOFFDIER, O ;
GAIDA, T ;
KATINGER, H ;
BURGER, W ;
GROSCHL, M ;
BENES, E .
BIOTECHNOLOGY PROGRESS, 1994, 10 (04) :428-432
[3]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[4]   A laminar flow expansion chamber facilitating downstream manipulation of particles concentrated using an ultrasonic standing wave [J].
Hawkes, JJ ;
Barrow, D ;
Cefai, J ;
Coakley, WT .
ULTRASONICS, 1998, 36 (08) :901-903
[5]   A continuous flow ultrasonic cell-filtering method [J].
Hawkes, JJ ;
Coakley, WT .
ENZYME AND MICROBIAL TECHNOLOGY, 1996, 19 (01) :57-62
[6]   Filtration of bacteria and yeast by ultrasound-enhanced sedimentation [J].
Hawkes, JJ ;
Limaye, MS ;
Coakley, WT .
JOURNAL OF APPLIED MICROBIOLOGY, 1997, 82 (01) :39-47
[7]  
HIGISHITANI K, 1981, CHEM ENG SCI, V36, P1187
[8]   Ultrasonic standing wave removal of microorganisms from suspension in small batch systems [J].
Limaye, MS ;
Hawkes, JJ ;
Coakley, WT .
JOURNAL OF MICROBIOLOGICAL METHODS, 1996, 27 (2-3) :211-220
[9]  
Mandralis Z. I., 1990, FLUID PARTICLE SEP J, V3, P115
[10]  
Peterson S., 1986, Proceedings of the Eighth Annual Conference of the IEEE/Engineering in Medicine and Biology Society (Cat. No. 86CH2368-9), P154