Ultrasensitive biomems sensors based on microcantilevers patterned with environmentally responsive hydrogels

被引:126
作者
Hilt, JZ
Gupta, AK
Bashir, R [1 ]
Peppas, NA
机构
[1] Purdue Univ, NSF, Program Therapeut & Diagnost Devices, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Chem Engn, Biomat & Drug Delivery Labs, W Lafayette, IN 47907 USA
[3] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[4] Purdue Univ, Dept Biomed Engn, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
free-radical photopolymerization; micropatterning; microcantilever; hydrogel; BioMEMS; MEMS; microsensor; pH sensor;
D O I
10.1023/A:1025786023595
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An innovative platform was developed for ultrasensitive microsensors based on microcantilevers patterned with crosslinked copolymeric hydrogels. A novel UV free-radical photolithography process was utilized to precisely align and pattern environmentally responsive hydrogels onto silicon microcantilevers, after microcantilevers were fabricated and released. Specifically, a crosslinked poly(methacrylic acid) network containing high amounts of poly(ethylene glycol) dimethacrylate was prepared and investigated. Hydrogels were patterned onto the silicon microcantilevers utilizing a mask aligner to allow for precise positioning. The silicon surface was modified with gamma-methacryloxypropyl trimethoxysilane to gain covalent adhesion between the polymer and the silicon. The hydrogels sensed and responded to changes in environmental pH resulting in a variation in surface stress that deflected the microcantilever. The bending response of patterned cantilevers with a change in environmental pH was observed, showing the possibility to construct MEMS/BioMEMS sensors based on microcantilevers patterned with environmentally responsive hydrogels. An extraordinary maximum sensitivity of 1 nm/5 x 10(-5)DeltapH was observed, demonstrating the ultrasensitivity of this microsensor platform.
引用
收藏
页码:177 / 184
页数:8
相关论文
共 30 条
[11]   Detection and localization of individual antibody-antigen recognition events by atomic force microscopy [J].
Hinterdorfer, P ;
Baumgartner, W ;
Gruber, HJ ;
Schilcher, K ;
Schindler, H .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (08) :3477-3481
[12]   DIRECT MEASUREMENT OF THE FORCES BETWEEN COMPLEMENTARY STRANDS OF DNA [J].
LEE, GU ;
CHRISEY, LA ;
COLTON, RJ .
SCIENCE, 1994, 266 (5186) :771-773
[13]   Microactuators toward microwaves for responsive controlled drug delivery [J].
Low, LM ;
Seetharaman, S ;
He, KQ ;
Madou, MJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (1-2) :149-160
[14]  
LOWMAN AM, 1997, POLYM PREPR, V38, P622
[15]  
Oral E, 2000, STP PHARMA SCI, V10, P261
[16]  
Pappas N.A., 2001, ENCY MAT SCI TECHNOL, P3492
[17]  
Peppas N.A.M., 1986, HYDROGELS MED PHARM, DOI DOI 10.1201/9780429285097
[18]   PHYSIOLOGICALLY RESPONSIVE HYDROGELS [J].
PEPPAS, NA .
JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 1991, 6 (03) :241-246
[19]   Hydrogels in pharmaceutical formulations [J].
Peppas, NA ;
Bures, P ;
Leobandung, W ;
Ichikawa, H .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2000, 50 (01) :27-46
[20]   Polymers and gels as molecular recognition agents [J].
Peppas, NA ;
Huang, Y .
PHARMACEUTICAL RESEARCH, 2002, 19 (05) :578-587