Fabrication and performance of a three-dimensionally adjustable device for the amperometric detection of microchip capillary electrophoresis

被引:21
作者
Chen, G [1 ]
Bao, HM [1 ]
Yang, PY [1 ]
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
关键词
amperometric detection; aromatic amines; capillary electrophoresis; miniaturization;
D O I
10.1002/elps.200500503
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A microchip CE-amperometric detection (AD) system has been fabricated by integrating a two-dimensionally adjustable CE microchip and an AD cell containing a one-dimensionally adjustable disk detection electrode in a Plexiglas holder. It facilitates the precise 3-D alignment between the channel outlet and the detection electrode without a complicated 3-D manipulator. The performance of this unique system was demonstrated by separating five aromatic amines (1,4-phenyldiamine, aniline, 2-methylaniline, 4-chloroaniline, and 1-naphthylamine) of environmental concern. Factors influencing their separation and detection processes were examined and optimized. The five analytes have been well separated within 140 s in a 74 cm long separation channel at a separation voltage of +2500 V using a 10 mM phosphate buffer (pH 3.5). Highly linear response is obtained for the five analytes over the range 20-200 mu M with the detection limits ranging from 0.46 to 1.44 mu M, respectively. The present system demonstrated long-term stability and reproducibility with RSDs of less than 5% for the peak current (n = 9). The new approach for the microchannel-electrode alignment should find a wide range of applications in CE, flowing injection analysis, and other microfluidic analysis systems.
引用
收藏
页码:4632 / 4640
页数:9
相关论文
共 26 条
[11]  
Huang XJ, 1999, ELECTROANAL, V11, P969, DOI 10.1002/(SICI)1521-4109(199909)11:13<969::AID-ELAN969>3.0.CO
[12]  
2-K
[13]   In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat [J].
Martin, RS ;
Ratzlaff, KL ;
Huynh, BH ;
Lunte, SM .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1136-+
[14]   Determination of aromatic amines by solid-phase microextraction and gas chromatography mass spectrometry in water samples [J].
Müller, L ;
Fattore, E ;
Benfenati, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 791 (1-2) :221-230
[15]   Micro total analysis systems. 1. Introduction, theory, and technology [J].
Reyes, DR ;
Iossifidis, D ;
Auroux, PA ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2623-2636
[16]  
Vandaveer WR, 2002, ELECTROPHORESIS, V23, P3667, DOI 10.1002/1522-2683(200211)23:21<3667::AID-ELPS3667>3.0.CO
[17]  
2-W
[18]   Recent developments in electrochemical detection for microchip capillary electrophoresis [J].
Vandaveer, WR ;
Pasas-Farmer, SA ;
Fischer, DJ ;
Frankenfeld, CN ;
Lunte, SM .
ELECTROPHORESIS, 2004, 25 (21-22) :3528-3549
[19]  
Wang J, 2002, ELECTROPHORESIS, V23, P713, DOI 10.1002/1522-2683(200203)23:5<713::AID-ELPS713>3.0.CO
[20]  
2-7