Biocompatible interfaces for biosensors

被引:15
作者
Gill, A
Lillie, G
Farace, G
Vadgama, P
机构
[1] Queen Mary Univ London, IRC Biomed Mat, London E1 4NS, England
[2] Univ Manchester, Hope Hosp, Dept Clin Biochem, Manchester, Lancs, England
关键词
PVC; cellulose acetate; polyphenol; polypyrrole; microfluidic; biosensor; electrochemical; biocompatibility;
D O I
10.1080/03067310500155129
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical biosensors need to interface reliably with complex biological samples. The latter are characterized by high surface activity and the presence of numerous interferent molecules. Polymeric membranes through their ability to act as surface modifiers of biosensors and as selective barriers help to minimize selectivity and biocompatibility problems for biosensors. Membranes studied include those based oil PVC, polyether sulphone and cellulose acetate Variously incorporating surfactants and as unmodified films to create a spectrum of permeabilities and surface properties. Additionally, electropolymerized phenolics as thin films have been tested as surface modifiers for base Pt working electrodes. Polypyrrole loaded with protein affinity molecules call register impedimetric change following target molecule binding the avidin-biotin model system was used to exemplify this. Ultimately, fluid flow over a device call create a fully biocompatible, selective interface and operational viability was tested in preliminary studies using microfluid flow channels.
引用
收藏
页码:699 / 725
页数:27
相关论文
共 20 条
[1]   The polaron and bipolaron contributions to the electronic structure of polypyrrole films [J].
Appel, G ;
Böhme, O ;
Mikalo, R ;
Schmeisser, D .
CHEMICAL PHYSICS LETTERS, 1999, 313 (3-4) :411-415
[2]  
Bartlett PN, 1997, FOOD TECHNOL-CHICAGO, V51, P44
[3]   Poly(vinyl chloride), polysulfone and sulfonated polyether-ether sulfone composite membranes for glucose and hydrogen peroxide perm-selectivity in amperometric biosensors [J].
Benmakroha, Y ;
Christie, I ;
Desai, M ;
Vadgama, P .
ANALYST, 1996, 121 (04) :521-526
[4]  
Black J, 1999, BIOL PERFORMANCE MAT
[5]   Performance of glucose biosensor based on oxygen electrode in physiological fluids and at body temperature [J].
Gamburzev, S ;
Atanasov, P ;
Wilkins, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 30 (03) :179-183
[6]   HEPARINIZED POLYURETHANES - INVITRO AND INVIVO STUDIES [J].
HEYMAN, PW ;
CHO, CS ;
MCREA, JC ;
OLSEN, DB ;
KIM, SW .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (04) :419-436
[7]   DIAMOND-LIKE CARBON COATED MICROPOROUS POLYCARBONATE AS A COMPOSITE BARRIER FOR A GLUCOSE ENZYME ELECTRODE [J].
HIGSON, SPJ ;
VADGAMA, PM .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :125-133
[8]   Characterization of protein adsorption at the phosphorylcholine incorporated polymer-water interface [J].
Murphy, EF ;
Lu, JR ;
Lewis, AL ;
Brewer, J ;
Russell, J ;
Stratford, P .
MACROMOLECULES, 2000, 33 (12) :4545-4554
[9]   The reduced adsorption of proteins at the phosphoryl choline incorporated polymer-water interface [J].
Murphy, EF ;
Lu, JR ;
Brewer, J ;
Russell, J ;
Penfold, J .
LANGMUIR, 1999, 15 (04) :1313-1322
[10]  
MUTLU S, 1994, ACS SYM SER, V556, P71