An experimental study of the biomechanical stability of ultrasound-activated pinned (SonicWeld Rx® plus Resorb-X®) and screwed fixed (Resorb-X®) resorbable materials for osteosynthesis in the treatment of simulated craniosynostosis in sheep

被引:40
作者
Pilling, E.
Meissner, H.
Jung, R.
Koch, R.
Loukota, R.
Mai, R.
Reitemeier, B.
Richter, G.
Stadlinger, B.
Stelnicki, E.
Eckelt, U.
机构
[1] Tech Univ Dresden, Fac Med, Dept Maxillofacial Surg, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Sch Dent, Dept Prosthet Dent, D-8027 Dresden, Germany
[3] Tech Univ Dresden, Inst Med Comp Sci & Biomet, D-8027 Dresden, Germany
[4] Tech Univ Dresden, Dept Expt Surg, D-8027 Dresden, Germany
[5] Leeds Teaching Hosp, Leeds Dental Inst, Dept Maxillofacial Surg, Leeds, W Yorkshire, England
关键词
resorbable plates; SonicWeld; osteosynthesis; craniosynostosis;
D O I
10.1016/j.bjoms.2006.12.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
We compared a conventional resorbable screw osteosynthesis with a resorbable, ultrasound-activated pin osteosynthesis, and studied mechanical load capacity and operative handling. This new form of osteosynthesis aims to reduce operation times, and to avoid torque loads and screw fractures to achieve stability. A sheep craniotomy model simulated an operation for dysmorphia on an infant skull. Two rectangular craniotomies of equal size were created in 13 lamb skulls, and each refixed by different means: the first by mesh and 20 screws, and the second by mesh with 20 pins inserted with ultrasound activation. All osteosynthesis material consisted of resorbable amorphous poly-(D,L)-lactide (PDLLA) (Resorb-X(R), KLS Martin, Tuttlingen, Germany). The insertion time was recorded. The animals were killed at different times, and areas of the healing skull including the plates and pins or screws were removed and divided into sections, which were then tested. In total 74 pin-fixed and 77 screw-fixed samples were obtained. Bending and tensile tests were used to simulate different forms of loading. The time required for the insertion of pins was significantly shorter than for screws. The mechanical tests showed differences in the stability of the bond between the osteosynthesis plate and bone that depended on the osteosynthesis system and the length of time it was in the animal. The pin osteosynthesis gave a stable mechanical load capacity, which was significantly different from that of screw osteosynthesis. Advantages of ultrasound-assisted, resorbable, pin osteosynthesis, include optimum operative handling, reduced insertion time, avoidance of fractures of the fixation elements and higher three-dimensional load capacity. (C) 2007 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 18 条
[1]   Endoscopic craniectomy for early correction of craniosynostosis [J].
Barone, CM ;
Jimenez, DF .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 104 (07) :1965-1973
[2]   Biodegradierbare Miniplatten (Lactosorb®) bei Kranioosteoplastik – experimentelle Ergebnisse am schnell wachsenden, juvenilen MiniaturschweinBiodegradable miniplates in cranio-osteoplastic – experimental results in the fast growing infant minipig [J].
H.-J. Becker ;
J. Wiltfang ;
H.-A. Merten ;
H.-G. Luhr .
Mund-, Kiefer- und Gesichtschirurgie, 1999, 3 (5) :275-278
[3]  
Cartwright Cathy C, 2003, J Neurosci Nurs, V35, P130
[5]  
Imola M J, 2001, Arch Facial Plast Surg, V3, P79, DOI 10.1001/archfaci.3.2.79
[6]   Early management of craniosynostosis using endoscopic-assisted strip craniectomies and cranial orthotic molding therapy [J].
Jimenez, DF ;
Barone, CM ;
Cartwright, CC ;
Baker, L .
PEDIATRICS, 2002, 110 (01) :97-104
[7]   Endoscopic craniectomy for early surgical correction of sagittal craniosynostosis [J].
Jimenez, DF ;
Barone, CM .
JOURNAL OF NEUROSURGERY, 1998, 88 (01) :77-81
[8]   Intracranial migration of fixation wires following correction of craniosynostosis in an infant [J].
Kosaka, M ;
Miyanohara, T ;
Wada, Y ;
Kamiishi, H .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2003, 31 (01) :15-19
[9]   Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures:: A prospective clinical trial of two amorphous L-/DL-lactide copolymer 2-mm miniplate systems [J].
Landes, CA ;
Kriener, S ;
Menzer, M ;
Kovàcs, AF .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (02) :601-610
[10]  
Lane L.C., 1892, JAMA, V18, P49