Room-temperature preparation and characterization of poly (ethylene glycol)-coated silica nanoparticles for biomedical applications

被引:155
作者
Xu, H [1 ]
Yan, F [1 ]
Monson, EE [1 ]
Kopelman, R [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A | 2003年 / 66A卷 / 04期
关键词
room-temperature preparation; poly(ethylene glycol); silica nanoparticles; biocompatible PEG coating; biomedical applications;
D O I
10.1002/jbm.a.10057
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monodisperse, spherical, polyethylene glycol (PEG)-coated silica nanoparticles have been prepared at room temperature and characterized for the purpose of biomedical applications. The particles were synthesized by the hydrolysis of tetramethyl orthosilicate (TMOS) in alcohol media under catalysis by ammonia, and their size can range from about 50-350 nm in diameter. We studied the particle size and size distribution using a scanning electron microscope (SEM) and an asymmetric field-flow fractionation (AFFF) multiangle static light-scattering instrument. The chemical and/or physical binding of PEG to the silica nanoparticles was studied by infrared spectroscopy, and the weight percentage of PEG attached to the particles was quantified. The PEG-coated silica nanoparticles showed enhanced colloidal stability when redispersed into aqueous solutions from the dried state as a result of the steric stabilization function of the PEG polymer grafted on the surface of particles. A nonspecific protein-binding test was also carried out to show that the PEG coating can help reduce the protein adsorption onto the surface of the particles, relating to the biocompatibility of these PEG-coated particles. Also, the inclusion of magnetic nanoparticles into the silica particles was shown as an example of the possible applications of PEG-coated silica particles. These silica nanoparticles, as a matrix for encapsulation of certain reagents, have potential for applications to in vivo diagnosis, analysis, and measurements inside intact biologic systems. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:870 / 879
页数:10
相关论文
共 37 条
[1]  
Alcantar NA, 2000, J BIOMED MATER RES, V51, P343, DOI 10.1002/1097-4636(20000905)51:3<343::AID-JBM7>3.0.CO
[2]  
2-D
[3]   Effect of block and graft copolymers on the stability of colloidal silica [J].
Bijsterbosch, HD ;
Stuart, MAC ;
Fleer, GJ .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 210 (01) :37-42
[4]   Fluorescent nanosensors for intracellular chemical analysis: Decyl methacrylate liquid polymer matrix and ion exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells [J].
Brasuel, M ;
Kopelman, R ;
Miller, TJ ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2221-2228
[5]  
BRINKER JC, 1990, SOL GEL SCI PHYSICS
[6]   Preparation of ultrafine silica- and PEG-coated magnetite particles [J].
Butterworth, MD ;
Illum, L ;
Davis, SS .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2001, 179 (01) :93-102
[7]   Preparation of monosize silica spheres and their crystalline stack [J].
Chen, SL .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1998, 142 (01) :59-63
[8]   Optical nanosensors for chemical analysis inside single living cells. 2. Sensors for pH and calcium and the intracellular application of PEBBLE sensors [J].
Clark, HA ;
Kopelman, R ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4837-4843
[9]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[10]   'Stealth' corona-core nanoparticles surface modified by polyethylene glycol (PEG):: influences of the corona (PEG chain length and surface density) and of the core composition on phagocytic uptake and plasma protein adsorption [J].
Gref, R ;
Lück, M ;
Quellec, P ;
Marchand, M ;
Dellacherie, E ;
Harnisch, S ;
Blunk, T ;
Müller, RH .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 18 (3-4) :301-313