Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations

被引:25
作者
Zaidi, H [1 ]
机构
[1] Univ Hosp Geneva, Div Nucl Med, CH-1211 Geneva 14, Switzerland
关键词
Monte Carlo; photon cross-section library; photon transport; positron emission tomography (PET);
D O I
10.1109/23.901179
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The many applications of Monte Carlo modeling in nuclear medicine Imaging make it desirable to increase the accuracy and computational speed of Monte Carlo codes. The accuracy of Monte Carlo simulations strongly depends on the accuracy in the probability functions and, thus, on the cross-section libraries used for photon-transport calculations. A comparison between different photon cross-section libraries and parameterizations implemented in Monte Carlo simulation packages developed for positron emission tomography and the most recent Evaluated Photon Data Library (EPDL97) developed by the Lawrence Livermore National Laboratory, Livermore, CA, was performed for several human tissues and common detector materials for energies from I keV to 1 MeV. Different photon cross-section libraries and parameterizations show quite large variations when compared to the EPDL97 coefficients. This latter library is the more up-to-date complete and consistent library available, and was carefully designed in the form of look-up tables providing efficient data storage, access, and management. EPDL97 is already a standard in the nuclear reactor industry. Its use as a standard in the simulation of medical imaging systems will help to eliminate potential differences between the results obtained with different codes. Together with the optimization of the computing time performances of the Monte Carlo software package, Eidolon, photon transport in three-dimensional (3-D) positron emission tomography could be efficiently modeled to develop accurate scatter models and better understand scatter correction techniques.
引用
收藏
页码:2722 / 2735
页数:14
相关论文
共 39 条
[1]  
Adam LE, 1999, NUKLEARMED-NUCL MED, V38, P61
[2]  
[Anonymous], 1969, PHOTON CROSS SECTION
[3]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[4]  
Berger M. J., 1987, 873597 NBSIR
[5]   Comparison of x-ray cross sections for diagnostic and therapeutic medical physics [J].
Boone, JM ;
Chavez, AE .
MEDICAL PHYSICS, 1996, 23 (12) :1997-2005
[6]   ITS - THE INTEGRATED TIGER SERIES OF ELECTRON PHOTON TRANSPORT CODES - VERSION 3.0 [J].
HALBLEIB, JA ;
KENSEK, RP ;
VALDEZ, GD .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :1025-1030
[7]  
HARRISON RL, 1994, P 1993 NUCL SCI S ME, P1154
[8]   3-D PHANTOM TO SIMULATE CEREBRAL BLOOD-FLOW AND METABOLIC IMAGES FOR PET [J].
HOFFMAN, EJ ;
CUTLER, PD ;
DIGBY, WM ;
MAZZIOTTA, JC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :616-620
[9]  
Hubbell J. H., 1975, Journal of Physical and Chemical Reference Data, V4, P471, DOI 10.1063/1.555523
[10]   Review of photon interaction cross section data in the medical and biological context [J].
Hubbell, JH .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :R1-R22