Contrast-enhanced magnetic resonance angiography of the pulmonary vasculature - A review

被引:28
作者
Kauczor, HU [1 ]
机构
[1] Johannes Gutenberg Universitat Mainz, Radiol Klin, Dept Radiol, D-55131 Mainz, Germany
关键词
contrast medium; magnetic resonance angiography (MRA); pulmonary arteries; pulmonary embolism;
D O I
10.1097/00004424-199809000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance angiography (MRA) has been established as a powerful noninvasive imaging modality, Its applications to the study of the pulmonary vasculature have been hampered by a multitude of factors, such as respiratory and cardiac motion artifacts, saturation problems, long acquisition times, and limited spatial resolution, The recent introduction of contrast-enhanced MRA (CE-MRA) has greatly improved the potential for possible investigation of the pulmonary arteries under clinical conditions. Three-dimensional sequences with minimum TR and TE, a hip angle between 20 degrees and 60 degrees, and minimum slice thickness can he considered an optimal approach for breath-hold imaging combined with the automatic injection of contrast medium, Early studies have demonstrated the superiority of CE-MRA over nonenhanced techniques. The major indication for CE-MR4 of the pulmonary vasculature is pulmonary embolism, Here a sensitivity of 85% and specificity of 95% can be obtained. It can be complemented by perfusion imaging, ventilation imaging, functional measurements of the right ventricle, and MR venography of the pelvic and Femoral veins. Blood pool contrast agents will open new perspectives in the future. This at-title reviews the technical aspects of CE-MRA of the pulmonary vasculature, pathologic findings, and their interpretation as well as present and future clinical applications.
引用
收藏
页码:606 / 617
页数:12
相关论文
共 65 条
[1]   GD-DTPA-CASCADE-POLYMER - POTENTIAL BLOOD-POOL CONTRAST AGENT FOR MR-IMAGING [J].
ADAM, G ;
NEUERBURG, J ;
SPUNTRUP, E ;
MUHLER, A ;
SCHERER, K ;
GUNTHER, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :462-466
[2]   Accuracy of MR angiography compared with radionuclide scanning in identifying the cause of pulmonary arterial hypertension [J].
Bergin, CJ ;
Hauschildt, J ;
Rios, G ;
Belezzuoli, EV ;
Huynh, T ;
Channick, RN .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1549-1555
[3]   MAGNETIC-RESONANCE-IMAGING DETECTION OF AN EXPERIMENTAL PULMONARY PERFUSION DEFICIT USING A MACROMOLECULAR CONTRAST AGENT - POLYLYSINE-GADOLINIUM-DTPA(40) [J].
BERTHEZENE, Y ;
VEXLER, V ;
PRICE, DC ;
WISNERDUPON, J ;
MOSELEY, ME ;
AICHER, KP ;
BRASCH, RC .
INVESTIGATIVE RADIOLOGY, 1992, 27 (05) :346-351
[4]   Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging - Application to unilateral lung transplantation [J].
Berthezene, Y ;
Croisille, P ;
Bertocchi, M ;
Houzard, C ;
Bendib, K ;
Revel, D .
INVESTIGATIVE RADIOLOGY, 1997, 32 (06) :351-356
[5]   CONTRAST-ENHANCED MR IMAGING OF THE LUNG - ASSESSMENTS OF VENTILATION AND PERFUSION [J].
BERTHEZENE, Y ;
VEXLER, V ;
CLEMENT, O ;
MUHLER, A ;
MOSELEY, ME ;
BRASCH, RC .
RADIOLOGY, 1992, 183 (03) :667-672
[6]   GD-DTPA-POLYLYSINE ENHANCED PULMONARY TIME-OF-FLIGHT MR-ANGIOGRAPHY [J].
BOCK, JC ;
PISON, U ;
KAUFMANN, F ;
FELIX, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :473-476
[7]   Comparison of gadolinium-DTPA and macromolecular gadolinium-DTPA-polylysine for contrast-enhanced pulmonary time-of-flight magnetic resonance angiography [J].
Bock, JC ;
Kaufmann, F ;
Felix, R .
INVESTIGATIVE RADIOLOGY, 1996, 31 (10) :652-657
[8]   MR angiography of the thoracic vessels [J].
Bongartz, G ;
Boos, M ;
Winter, K ;
Brandli, M ;
Scheffler, K .
RADIOLOGE, 1997, 37 (07) :529-538
[9]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[10]   GADOLINIUM-ENHANCED MR ANGIOGRAPHY [J].
CREASY, JL ;
PRICE, RR ;
PRESBREY, T ;
GOINS, D ;
PARTAIN, CL ;
KESSLER, RM .
RADIOLOGY, 1990, 175 (01) :280-283