A method is presented for measurement of perfusion changes during brain activation using a single-shot pulsed spin labeling technique. By employing a double-inversion labeling strategy, stationary tissue (background) signal was suppressed while minimally affecting perfusion sensitivity. This allowed omission of the otherwise required reference scan, resulting in twofold-improved temporal resolution. The method was applied to visual and motor cortex activation studies in humans, and compared to standard FAIR-type perfusion labeling techniques. Experiments performed at 1.5T and 3.0T indicate a close to 90% suppression of background signal, at a cost of an 11% and 9%, respectively reduction in perfusion signal. Combined with the twofold increase in signal averaging, and a reduction in background signal fluctuations, this resulted in a 64% (1.5T, N = 3) and a 128% (3T, N = 4) overall improvement in sensitivity for the detection of activation-related perfusion changes. Published 2001 Wiley-Liss, Inc.(dagger)
引用
收藏
页码:88 / 94
页数:7
相关论文
共 13 条
[1]   INFLOW VERSUS DEOXYHEMOGLOBIN EFFECTS IN BOLD FUNCTIONAL MRI USING GRADIENT ECHOES AT 1.5 T [J].
DUYN, JH ;
MOONEN, CTW ;
VANYPEREN, GH ;
DEBOER, RW ;
LUYTEN, PR .
NMR IN BIOMEDICINE, 1994, 7 (1-2) :83-88
[2]  
DUYN JH, 1992, RADIOLOGY, V183, P711
[3]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[4]   MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING [J].
KWONG, KK ;
CHESLER, DA ;
WEISSKOFF, RM ;
DONAHUE, KM ;
DAVIS, TL ;
OSTERGAARD, L ;
CAMPBELL, TA ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :878-887
[5]   DYNAMIC MAGNETIC-RESONANCE-IMAGING OF HUMAN BRAIN ACTIVITY DURING PRIMARY SENSORY STIMULATION [J].
KWONG, KK ;
BELLIVEAU, JW ;
CHESLER, DA ;
GOLDBERG, IE ;
WEISSKOFF, RM ;
PONCELET, BP ;
KENNEDY, DN ;
HOPPEL, BE ;
COHEN, MS ;
TURNER, R ;
CHENG, HM ;
BRADY, TJ ;
ROSEN, BR .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1992, 89 (12) :5675-5679
[6]   DISCRIMINATION OF LARGE VENOUS VESSELS IN TIME-COURSE SPIRAL BLOOD-OXYGEN-LEVEL-DEPENDENT MAGNETIC-RESONANCE FUNCTIONAL NEUROIMAGING [J].
LEE, AT ;
GLOVER, GH ;
MEYER, CH .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (06) :745-754
[7]  
MANI S, 1997, P 5 SCI M INT SOC MA, P1758
[8]   TESLA GRADIENT RECALLED ECHO CHARACTERISTICS OF PHOTIC STIMULATION-INDUCED SIGNAL CHANGES IN THE HUMAN PRIMARY VISUAL-CORTEX [J].
MENON, RS ;
OGAWA, S ;
TANK, DW ;
UGURBIL, K .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :380-386
[9]   BRAIN MAGNETIC-RESONANCE-IMAGING WITH CONTRAST DEPENDENT ON BLOOD OXYGENATION [J].
OGAWA, S ;
LEE, TM ;
KAY, AR ;
TANK, DW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (24) :9868-9872
[10]   A comparison of fast MR scan techniques for cerebral activation studies at 1.5 Tesla [J].
Yang, YH ;
Glover, GH ;
van Gelderen, P ;
Patel, AC ;
Mattay, VS ;
Frank, JA ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (01) :61-67