Normative findings of electrically evoked compound action potential measurements uing the neural response telemetry of the nucleus CI24M cochlear implant system

被引:87
作者
Dees, DC
Dillier, N
Lai, WK
von Wallenberg, E
van Dijk, B
Akdas, F
Aksit, M
Batman, C
Beynon, A
Burdo, S
Chanal, JM
Collet, L
Conway, M
Coudert, C
Craddock, L
Cullington, H
Deggouj, N
Fraysse, B
Grabel, S
Kiefer, J
Kiss, JG
Lenarz, T
Mair, A
Maune, S
Müller-Deile, J
Piron, JP
Razza, S
Tasche, C
Thai-Van, H
Toth, F
Truy, E
Uziel, A
Smoorenburg, GF
机构
[1] Cochlear Europe Ltd, London, England
[2] UCL, London, England
[3] Univ Hosp Birmingham, Birmingham, W Midlands, England
[4] Univ Southampton, Southampton, Hants, England
[5] Univ Hosp, Zurich, Switzerland
[6] Cochlear AG, Basel, Switzerland
[7] Cochlear Technol Ctr, Antwerp, Belgium
[8] Clin Univ St Luc, ORL, B-1200 Brussels, Belgium
[9] Duysel Audiol Ctr, Istanbul, Turkey
[10] Univ Hosp, Nijmegen, Netherlands
[11] Univ Utrecht Hosp, Utrecht, Netherlands
[12] Osped Circolo Varese, Varese, Italy
[13] Fdn Macchi, Varese, Italy
[14] Hop Edouard Herriot, Lyon, France
[15] CNRS, UMR 5020, Lab Neurosci & Syst Sensoriels, Lyon, France
[16] Newmed SA, Toulouse, France
[17] Purpan Hosp, Toulouse, France
[18] CHU Montpellier, Montpellier, France
[19] Cochlear GmbH, Hannover, Germany
[20] Univ Hosp, Berlin, Germany
[21] Univ Hosp, Frankfurt, Germany
[22] Hannover Med Sch, Hannover, Germany
[23] Christian Albrechts Univ Kiel Klinikum, Kiel, Germany
[24] House Ear Res Inst, Los Angeles, CA USA
[25] Univ Szeged, Szeged, Hungary
[26] Univ Med Sch, Salzburg, Austria
关键词
cochlear implant; neural response telemetry; electrically evoked compound action potential;
D O I
10.1159/000083366
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
One hundred and forty-seven adult recipients of the Nucleus(R) 24 cochlear implant system, from 13 different European countries, were tested using neural response telemetry to measure the electrically evoked compound action potential ( ECAP), according to a standardised postoperative measurement procedure. Recordings were obtained in 96% of these subjects with this standardised procedure. The group results are presented in terms of peak amplitude and latency, slope of the amplitude growth function and ECAP threshold. The effects of aetiological factors and the duration of deafness on the ECAP were also studied. While large intersubject variability and intrasubject variability ( across electrodes) were found, results fell within a consistent pattern and a normative range of peak amplitudes and latencies was established. The aetiological factors had little effect on the ECAP characteristics. However, age affected ECAP amplitude and slope of the amplitude growth function significantly; i.e., the amplitude is higher in the lowest age category ( 15-30 years). Principal component analysis of the ECAP thresholds shows that the thresholds across 5 electrodes can be described by two factors accounting for 92% of the total variance. The two factors represent the overall level of the threshold profiles ('shift') and their slopes across the electrode array ('tilt'). Correlation between these two factors and the same factors describing the T- and C-levels appeared to be moderate, in the range of 0.5-0.6.
引用
收藏
页码:105 / 116
页数:12
相关论文
共 20 条
[1]   Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential [J].
Abbas, PJ ;
Brown, CJ ;
Shallop, JK ;
Firszt, JB ;
Hughes, ML ;
Hong, SH ;
Staller, SJ .
EAR AND HEARING, 1999, 20 (01) :45-59
[2]   ELECTRICALLY ELICITED STAPEDIUS REFLEX IN COCHLEAR IMPLANT PATIENTS [J].
BATTMER, RD ;
LASZIG, R ;
LEHNHARDT, E .
EAR AND HEARING, 1990, 11 (05) :370-374
[3]   ELECTRICALLY EVOKED WHOLE-NERVE ACTION-POTENTIALS - DATA FROM HUMAN COCHLEAR IMPLANT USERS [J].
BROWN, CJ ;
ABBAS, PJ ;
GANTZ, B .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (03) :1385-1391
[4]   The relationship between EAP and EABR thresholds and levels used to program the nucleus 24 speech processor: Data from adults [J].
Brown, CJ ;
Hughes, ML ;
Luk, B ;
Abbas, PJ ;
Wolaver, A ;
Gervais, J .
EAR AND HEARING, 2000, 21 (02) :151-163
[5]  
Craddock L, 2003, Cochlear Implants Int, V4, P161, DOI 10.1179/cim.2003.4.4.161
[6]   Measurement of the electrically evoked compound action potential via a neural response telemetry system [J].
Dillier, N ;
Lai, WK ;
Almqvist, B ;
Frohne, C ;
Müller-Deile, J ;
Stecker, M ;
von Wallenberg, E .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (05) :407-414
[7]   A model of a Nucleus 24 cochlear implant fitting protocol based on the electrically evoked whole nerve action potential [J].
Franck, KH .
EAR AND HEARING, 2002, 23 (01) :67S-71S
[8]  
Kiefer J, 2001, AUDIOLOGY, V40, P32
[9]  
KILENY PR, 1994, ARCH OTOLARYNGOL, V120, P1083
[10]   ADAPTATION IN THE COMPOUND ACTION-POTENTIAL RESPONSE OF THE GUINEA-PIG 8TH NERVE TO ELECTRIC-STIMULATION [J].
KILLIAN, MJP ;
KLIS, SFL ;
SMOORENBURG, GF .
HEARING RESEARCH, 1994, 81 (1-2) :66-82