The Effect of Balconies on Ventilation Performance of Low-rise Buildings

被引:38
作者
Ai, Z. T. [1 ,2 ]
Mak, C. M. [1 ]
Niu, J. L. [1 ]
Li, Z. R. [2 ]
Zhou, Q. [3 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Tongji Univ, Coll Mech Engn, Shanghai 200092, Peoples R China
[3] Purdue Univ, Dept Mech Engn, W Lafayette, IN 47907 USA
关键词
Balconies; CFD; Natural ventilation; Low-rise buildings; COMPUTATIONAL FLUID-DYNAMICS; TROPICAL HUMID REGION; NATURAL VENTILATION; NUMERICAL-SIMULATION; WIND-TUNNEL; DESIGN; PREDICTION; FLOW; CFD;
D O I
10.1177/1420326X11409457
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Chand et al. conducted experiments in a low speed wind tunnel to study the effect of balconies on the ventilative force on low-rise buildings without openings. Using their model, this study intends to investigate indoor ventilation performance by examining mass flow rate and average velocity on the working plane using computational fluid dynamics. Simulations were validated against their experiments. The numerical results indicate that, for single-sided ventilation, the provision of balconies increases mass flow rate and reduces average velocity on the working plane in most rooms, but for cross ventilation, this provision has no significant effect under normally or obliquely incident wind conditions. After the addition of balconies, the worst ventilation circumstances on the windward side under single-sided ventilation conditions were found on the intermediate floor. The simulation results also showed that, in many cases, wind flows into and out of the rooms through the left or right side of the opening rather than through the bottom and top of the opening, especially in the case of buildings that are obliquely oriented to the air stream. This phenomenon demonstrates that predictions of single-sided ventilative force using data relating to the bottom and top parts of the opening are not accurate enough.
引用
收藏
页码:649 / 660
页数:12
相关论文
共 23 条
[1]   Using CFD to investigate ventilation characteristics of vaults as wind-inducing devices in buildings [J].
Asfour, Omar S. ;
Gadi, Mohamed B. .
APPLIED ENERGY, 2008, 85 (12) :1126-1140
[2]   A comparison between CFD and Network models for predicting wind-driven ventilation in buildings [J].
Asfour, Omar S. ;
Gadi, Mohamed B. .
BUILDING AND ENVIRONMENT, 2007, 42 (12) :4079-4085
[3]   Experimental validation of a computational fluid dynamics code to predict the wind speed in street canyons for passive cooling purposes [J].
Assimakopoulos, V. D. ;
Georgakis, C. ;
Santamouris, M. .
SOLAR ENERGY, 2006, 80 (04) :423-434
[4]  
*BUILD DEP, 2001, 1 BUILD DEP GREEN IN
[5]   Effect of balconies on ventilation inducing aeromotive force on low-rise buildings [J].
Chand, I ;
Bhargava, PK ;
Krishak, NLV .
BUILDING AND ENVIRONMENT, 1998, 33 (06) :385-396
[6]   Ventilation performance prediction for buildings: Model assessment [J].
Chen, Qingyan ;
Lee, Kisup ;
Mazumdar, Sagnik ;
Poussou, Stephane ;
Wang, Liangzhu ;
Wang, Miao ;
Zhang, Zhao .
BUILDING AND ENVIRONMENT, 2010, 45 (02) :295-303
[7]   Ventilation performance prediction for buildings: A method overview and recent applications [J].
Chen, Qingyan .
BUILDING AND ENVIRONMENT, 2009, 44 (04) :848-858
[8]  
Cheng Y, 2003, J WIND ENG IND AEROD, V91, P1301, DOI [10.1016/j.jweia.2003.08.001, 10.1016/j.jweia.2003.08.004]
[9]   The influence of an architectural design alternative (transoms) on indoor air environment in conventional kitchens in Taiwan [J].
Chiang, CM ;
Lai, CM ;
Chou, PC ;
Li, YY .
BUILDING AND ENVIRONMENT, 2000, 35 (07) :579-585
[10]   Simulation of wind-driven ventilative cooling systems for an apartment building in Beijing and Shanghai [J].
da Graça, GC ;
Chen, Q ;
Glicksman, LR ;
Norford, LK .
ENERGY AND BUILDINGS, 2002, 34 (01) :1-11