Apparent Young's modulus of human radius using inverse finite-element method

被引:55
作者
Bosisio, M. R.
Talmant, M.
Skalli, W.
Laugier, P.
Mitton, D. [1 ]
机构
[1] CNRS, ENSAM, Lab Biomecan, F-75700 Paris, France
[2] Univ Paris 06, CNRS, Lab Imagerie Parametr, F-75005 Paris, France
关键词
cortical bone; breaking load; compression; biomechanics; strain;
D O I
10.1016/j.jbiomech.2006.09.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The ability to assess the elastic and failure properties of cortical bone at the radial diaphysis has a clinical importance. A new generation of quantitative ultrasound (QUS) devices and peripheral quantitative computed tomography (p-QCT) has been developed to assess non-invasively bone material and structural properties at the distal radius. This anatomical site is characterized by a thin cortical thickness that complicates traditional mechanical testing methods on specimens. Until now, mechanical properties of cortical bone at distal radius (e.g., elastic modulus, yield stress and strain) remain rarely studied probably due to experimental difficulties. The present study introduces an inverse finite-element method strategy to measure the elastic modulus and yield properties of human cortical specimens of the radial diaphysis. Twenty millimeter- thick portions of diaphysis were cut from 40 human radii (ages 45-90) for biornechanical test. Subsequently the same portion was modeled in order to obtain a specimen- specific three dimensional finite-element model (3D-FEM). Longitudinal elastic constants at the apparent level and stress characterizations were performed by coupling mechanical parameters with isotropic linear-elastic simulations. The results indicated that the mean apparent Young's modulus for radial cortical bone was 16 GPa (SD 1.8) and the yield stress was 153 MPa (SID 33). Breaking load was 12,946 N (SD 3644), cortical thickness 2.9mm (SD 0.6), structural effective strain at the yield (epsilon(y) = 0.0097) and failure (epsilon(y) = 0.0154) load were also calculated. The 3D-FEM strategy described here may help to investigate bone mechanical properties when some difficulties arise from machining mechanical sample. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2022 / 2028
页数:7
相关论文
共 29 条
[1]
A new method for quantitative ultrasound measurements at multiple skeletal sites -: First Results of precision and fracture discrimination [J].
Barkmann, R ;
Kantorovich, E ;
Singal, C ;
Hans, D ;
Genant, HK ;
Heller, M ;
Glüer, CC .
JOURNAL OF CLINICAL DENSITOMETRY, 2000, 3 (01) :1-7
[2]
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[3]
An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity [J].
Bossy, E ;
Talmant, M ;
Peyrin, F ;
Akrout, L ;
Cloetens, P ;
Laugier, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (09) :1548-1556
[4]
Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: A validation on test materials [J].
Bossy, E ;
Talmant, M ;
Defontaine, M ;
Patat, F ;
Laugier, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (01) :71-79
[5]
THE ELASTIC-MODULI OF HUMAN SUBCHONDRAL, TRABECULAR, AND CORTICAL BONE TISSUE AND THE SIZE-DEPENDENCY OF CORTICAL BONE MODULUS [J].
CHOI, K ;
KUHN, JL ;
CIARELLI, MJ ;
GOLDSTEIN, SA .
JOURNAL OF BIOMECHANICS, 1990, 23 (11) :1103-1113
[6]
DEVIATORIC AND HYDROSTATIC MODE INTERACTION IN HARD AND SOFT-TISSUE [J].
COWIN, SC .
JOURNAL OF BIOMECHANICS, 1990, 23 (01) :11-14
[7]
Forearm fractures as predictors of subsequent osteoporotic fractures [J].
Cuddihy, MT ;
Gabriel, SE ;
Crowson, CS ;
O'Fallon, WM ;
Melton, LJ .
OSTEOPOROSIS INTERNATIONAL, 1999, 9 (06) :469-475
[8]
Osteoporosis intervention following distal forearm fractures - A missed opportunity [J].
Cuddihy, MT ;
Gabriel, SE ;
Crowson, CS ;
Atkinson, EJ ;
Tabini, C ;
O'Fallon, M ;
Melton, LJ .
ARCHIVES OF INTERNAL MEDICINE, 2002, 162 (04) :421-426
[9]
Dong XN, 2004, J BIOMECH, V37, P1281, DOI [10.1016/j.jbiomech.2003.12.011, 10.1016/j.biomech.2003.12.011]
[10]
Strength prediction of the distal radius by bone densitometry -: Evaluation using biomechanical tests [J].
Eckstein, F ;
Kuhn, V ;
Lochmüller, EM .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (03) :487-503