Indirect comparison of two quantitative immunochemical faecal occult blood tests in a population with average colorectal cancer risk

被引:6
作者
Guittet, L. [1 ]
Bailly, L. [1 ]
Bouvier, V. [1 ]
Launoy, G. [1 ]
机构
[1] Univ Caen, INSERM Canc & Populat ERI3, Fac Med, Caen Univ Hosp CHU, F-14032 Caen, France
关键词
PERFORMANCE; NUMBER;
D O I
10.1258/jms.2011.011012
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Magstream and OC Sensor quantitative immunochemical faecal occult blood tests (IFOBT) have shown better performances than guaiac (G) tests in colorectal cancer screening, however Magstream and OC Sensor have never been compared. We hypothesized that similar performances could be observed with Magstream and OC Sensors, provided a similar cut-off (expressed in concentration of haemoglobin in the stools) is used. We performed a literature-based indirect comparison between these tests, taking into account the cut-off, the number of samples, and the way they were combined (I2+: at least one positive sample of 2; I2++: both positive samples; I-1: only one sample). Six studies conducted in general average-risk populations were included in this review. For each [test]*[cut-off], positivity rate (PR) decreased and predictive positive value (PPV) increased from I2+ to I-1 and I2++. For similar PR, PPV with OC Sensor was greater than with Magstream. This could be due to factors other than the test, because PPVs associated with GFOBT in studies evaluating OC Sensor were greater than PPVs associated with GFOBT in the study evaluating Magstream. Direct comparison between Magstream and OC Sensor is needed to confirm the suspected superiority of OC Sensor.
引用
收藏
页码:76 / 81
页数:6
相关论文
共 13 条
[1]   Basic variables at different positivity thresholds of a quantitative immunochemical test for faecal occult blood [J].
Castiglione, G ;
Grazzini, G ;
Miccinesi, G ;
Rubeca, T ;
Sani, C ;
Turco, P ;
Zappa, M .
JOURNAL OF MEDICAL SCREENING, 2002, 9 (03) :99-103
[2]  
GOULARD H, 2009, FRENCH COLORECTAL CA
[3]   Immunochemical faecal occult blood test: number of samples and positivity cutoff. What is the best strategy for colorectal cancer screening? [J].
Grazzini, G. ;
Visioli, C. B. ;
Zorzi, M. ;
Ciatto, S. ;
Banovich, F. ;
Bonanomi, A. G. ;
Bortoli, A. ;
Castiglione, G. ;
Cazzola, L. ;
Confortini, M. ;
Mantellini, P. ;
Rubeca, T. ;
Zappa, M. .
BRITISH JOURNAL OF CANCER, 2009, 100 (02) :259-265
[4]   Analytical Comparison of Three Quantitative Immunochemical Fecal Occult Blood Tests for Colorectal Cancer Screening [J].
Guittet, Lydia ;
Guillaume, Elodie ;
Levillain, Romuald ;
Beley, Philippe ;
Tichet, Jean ;
Lantieri, Olivier ;
Launoy, Guy .
CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2011, 20 (07) :1492-1501
[5]   Performance of immunochemical faecal occult blood test in colorectal cancer screening in average-risk population according to positivity threshold and number of samples [J].
Guittet, Lydia ;
Bouvier, Veronique ;
Mariotte, Nicole ;
Vallee, Jean-Pierre ;
Levillain, Romuald ;
Tichet, Jean ;
Launoy, Guy .
INTERNATIONAL JOURNAL OF CANCER, 2009, 125 (05) :1127-1133
[6]   Cochrane systematic review of colorectal cancer screening using the fecal occult blood test (Hemoccult): An update [J].
Hewitson, Paul ;
Glasziou, Paul ;
Watson, Eila ;
Towler, Bernie ;
Irwig, Les .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (06) :1541-1549
[7]   Screening for colorectal cancer: random comparison of guaiac and immunochemical faecal occult blood testing at different cut-off levels [J].
Hol, L. ;
Wilschut, J. A. ;
van Ballegooijen, M. ;
van Vuuren, A. J. ;
van der Valk, H. ;
Reijerink, J. C. I. Y. ;
van der Togt, Acm ;
Kuipers, E. J. ;
Habbema, J. D. F. ;
van Leerdam, Me .
BRITISH JOURNAL OF CANCER, 2009, 100 (07) :1103-1110
[8]   Variation in polyp detection rates at screening colonoscopy [J].
Imperiale, Thomas F. ;
Glowinski, Elizabeth A. ;
Juliar, Beth E. ;
Azzouz, Faouzi ;
Ransohoff, David F. .
GASTROINTESTINAL ENDOSCOPY, 2009, 69 (07) :1288-1295
[9]   Interobserver variability in the pathological assessment of malignant colorectal polyps [J].
Komuta, K ;
Batts, K ;
Jessurun, J ;
Snover, D ;
Garcia-Aguilar, J ;
Rothenberger, D ;
Madoff, R .
BRITISH JOURNAL OF SURGERY, 2004, 91 (11) :1479-1484
[10]   Evaluation of an immunochemical fecal occult blood test with automated reading in screening for colorectal cancer in a general average-risk population [J].
Launoy, GD ;
Bertrand, HJ ;
Berchi, C ;
Talbourdet, VY ;
Guizard, AVN ;
Bouvier, VM ;
Caces, ER .
INTERNATIONAL JOURNAL OF CANCER, 2005, 115 (03) :493-496