A functionalized gold nanoparticles and Rhodamine 6G based fluorescent sensor for high sensitive and selective detection of mercury(II) in environmental water samples

被引:120
作者
Jinlong Chen [1 ]
AiFang Zheng
AiHong Chen
Yingchun Gao
Chiyang He
Xiaoming Kai
Genhua Wu
Youcun Chen
机构
[1] Anqing Normal Coll, Sch Chem & Chem Engn, Anhui Key Lab Funct Mol, Anqing 246003, Peoples R China
[2] Anqing Normal Coll, Dept Life Sci, Anqing 246003, Peoples R China
关键词
gold particles; Rhodamine; 6G; fluorescence sensor; Mercury(II); RESONANCE ENERGY-TRANSFER; FLOW-INJECTION; SPECTROPHOTOMETRIC DETERMINATION; CYSTEINE; IONS; HG2+; PRECONCENTRATION; CHEMODOSIMETER; SPECTROMETRY; SEDIMENT;
D O I
10.1016/j.aca.2007.07.074
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gold-nanoparticles (Au NPs)-Rhodamine 6G (Rh6G) based fluorescent sensor for detecting Hg(II) in aqueous solution has been developed. Water-soluble and monodisperse gold nanoparticles (An NPs) has been prepared facilely and further modified with thioglycolic acid (TGA). Free Rh6G dye was strongly fluorescent in bulk solution. The sensor system composing of Rh6G and An NPs fluoresce weakly as result of fluorescence resonance energy transfer (FRET) and collision. The fluorescence of Rh6G and Au NPs based sensor was gradually recovered due to Rh6G units departed from the surface of functionalized Au NPs in the presence of Hg(II). Based on the modulation of fluorescence quenching efficiency of Rh6G-Au NPs by Hg(II) at pH 9.0 of teraborate buffer solution, a simple, rapid, reliable and specific turn-on fluorescent assay for Hg(II) was proposed. Under the optimum conditions, the fluorescence intensity of sensor is proportional to the concentration of Hg(II). The calibration graphs are linear over the range of 5.0 x 10(-10) to 3.55 x 10(-8) mol L-1, and the corresponding limit of detection (LOD) is low as 6.0 x 10(-11) mol L-1. The relative standard deviation of 10 replicate measurements is 1.5% for 2.0 x 10(-9) mol L-1 Hg(II). In comparison with conventional fluorimetric methods for detection of mercury ion, the present nanosensor endowed with higher sensitivity and selectivity for Hg(II) in aqueous solution. Mercury(H) of real environmental water samples was determined by our proposed method with satisfactory results that were obtained by atomic absorption spectroscopy (AAS). (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 52 条
[21]   Efficient quenching of the fluorescence of binaphthyl-based amphiphiles by mercury(II) complexes [J].
Juskowiak, B .
ANALYTICA CHIMICA ACTA, 1996, 320 (01) :115-124
[22]  
Kamat PV, 2002, ANGEW CHEM INT EDIT, V41, P2764, DOI 10.1002/1521-3773(20020802)41:15<2764::AID-ANIE2764>3.0.CO
[23]  
2-E
[24]   Development of a 'collect and punch' cold vapour inductively coupled plasma mass spectrometric method for the direct determination of mercury at nanograms per litre levels [J].
Karunasagar, D ;
Arunachalam, J ;
Gangadharan, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :679-682
[25]   Modulating the sensory response of a conjugated polymer by proteins: An agglutination assay for mercury ions in water [J].
Kim, IB ;
Bunz, UHF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (09) :2818-2819
[26]   Hg2+-selective OFF-ON and Cu2+-selective ON-OFF type fluoroionophore based upon cyclam [J].
Kim, SH ;
Kim, JS ;
Park, SM ;
Chang, SK .
ORGANIC LETTERS, 2006, 8 (03) :371-374
[27]   Determination of mercury by cold-vapor atomic absorption spectrometry with preconcentration on a gold-trap [J].
Kopysc, E ;
Pyrzynska, K ;
Garbos, S ;
Bulska, E .
ANALYTICAL SCIENCES, 2000, 16 (12) :1309-1312
[28]   Glutathione- and cysteine-induced transverse overgrowth on gold nanorods [J].
Kou, Xiaoshan ;
Zhang, Shuzhuo ;
Yang, Zhi ;
Tsung, Chia-Kuang ;
Stucky, Galen D. ;
Sun, Lingdong ;
Wang, Jianfang ;
Yan, Chunhua .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (20) :6402-+
[29]  
LANDOR MS, 1999, ANAL CHIM ACTA, V388, P19
[30]   Colorimetric detection of mercuric ion (Hg2+) in aqueous media using DNA-functionalized gold nanoparticles [J].
Lee, Jae-Seung ;
Han, Min Su ;
Mirkin, Chad A. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (22) :4093-4096