Charge-coupled device operated in a time-delayed integration mode as an approach to high-throughput flow-based single molecule analysis

被引:17
作者
Emory, Jason M.
Soper, Steven A. [1 ]
机构
[1] Louisiana State Univ, Dept Chem, Dept Mech Engn, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Ctr BioModular Multi Scale Syst, Baton Rouge, LA 70803 USA
关键词
D O I
10.1021/ac800447x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Single molecule detection (SMD) readouts are particularly attractive for assays geared toward high-throughput processing, because they can potentially reduce assay time by eliminating various processing steps. Unfortunately, most flow-based SMD experiments have generated low throughputs due primarily to the fact that they are configured in single assay formats. The use of a charge-coupled device (CCD) with flow-based SMD can image multiple single molecule assays simultaneously to realize high-throughput processing capabilities. We present, for the first time, the ability to simultaneously track and detect single molecules in multiple microfluidic channels by employing a CCD camera operated in time-delayed integration (TDI) mode as a means for increasing the throughput of any single molecule measurement. As an example of the technology, we have configured a CCD to operate in a TDI mode to detect single double-stranded DNA molecules (lambda and pBR322) labeled with an intercalating dye (TOTO-3) in a series of microfluidic channels poised on a poly(methyl methacrylate), PMMA, chip. A laser beam was launched into the side of the chip, which irradiated a series of fluidic channels (eight) with the resulting fluorescence imaged onto a CCD. Using this system, we were able to identify single DNA molecules based on the fluorescence burst intensity arising from differences in the extent of dye labeling associated with the DNA molecule length. The CCD/TDI approach allowed increasing sample throughput by a factor of 8 compared to a single-assay SMD experiment. A sampling throughput of 276 molecules s(-1) per channel and 2208 molecules s(-1) for an eight channel microfluidic system was demonstrated. Operated in its full capacity, this multichannel format was projected to yield a sample throughput of 1.7 x 10(7) molecules s(-1), which represents a 170-fold improvement over previously reported single molecule sampling rates.
引用
收藏
页码:3897 / 3903
页数:7
相关论文
共 24 条
[1]   IMPLEMENTING CHEMICAL SENSORS IN INDUSTRY - NOVEL APPROACHES [J].
BLOM, N ;
FETTINGER, JC ;
KOCH, J ;
LUDI, H ;
MANZ, A ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) :75-78
[2]   SIDE EXCITATION OF FLUORESCENCE IN ULTRATHIN SLAB GEL-ELECTROPHORESIS [J].
CHEN, DH ;
PETERSON, MD ;
BRUMLEY, RL ;
GIDDINGS, MC ;
BUXTON, EC ;
WESTPHALL, M ;
SMITH, L ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1995, 67 (19) :3405-3411
[3]   Single-molecule fluorescence detection in microfluidic channels -: the Holy Grail in μTAS? [J].
Dittrich, PS ;
Manz, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) :1771-1782
[4]   Charge-transfer devices in analytical instrumentation [J].
Hanley, QS ;
Earle, CW ;
Pennebaker, FM ;
Madden, SP ;
Denton, MB .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :A661-A667
[5]   RNA expression profiling at the single molecule level [J].
Hesse, Jan ;
Jacak, Jaroslaw ;
Kasper, Maria ;
Regl, Gerhard ;
Eichberger, Thomas ;
Winklmayr, Martina ;
Aberger, Fritz ;
Sonnleitner, Max ;
Schlapak, Robert ;
Howorka, Stefan ;
Muresan, Leila ;
Frischauf, Anna-Maria ;
Schuetz, Gerhard J. .
GENOME RESEARCH, 2006, 16 (08) :1041-1045
[6]   High-throughput measurements of biochemical responses using the plate::vision multimode 96 minilens array reader [J].
Huang, Kuo-Sen ;
Mark, David ;
Gandenberger, Frank Ulrich .
MEASURING BIOLOGICAL RESPONSES WITH AUTOMATED MICROSCOPY, 2006, 414 :589-600
[7]   CAPILLARY ARRAY ELECTROPHORESIS USING LASER-EXCITED CONFOCAL FLUORESCENCE DETECTION [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :967-972
[8]   Evaluation of micromilled metal mold masters for the replication of microchip electrophoresis devices [J].
Hupert, Mateusz L. ;
Guy, W. Jason ;
Llopis, Shawn D. ;
Shadpour, Hamed ;
Rani, Sudheer ;
Nikitopoulos, Dimitris E. ;
Soper, Steven A. .
MICROFLUIDICS AND NANOFLUIDICS, 2007, 3 (01) :1-11
[9]   LINE SCANNING SYSTEM FOR DIRECT DIGITAL CHEMILUMINESCENCE IMAGING OF DNA-SEQUENCING BLOTS [J].
KARGER, AE ;
WEISS, R ;
GESTELAND, RF .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1785-1793
[10]   OPTIMIZATION OF EXCITATION AND DETECTION GEOMETRY FOR MULTIPLEXED CAPILLARY ARRAY ELECTROPHORESIS OF DNA FRAGMENTS [J].
LU, XD ;
YEUNG, ES .
APPLIED SPECTROSCOPY, 1995, 49 (05) :605-609