Upper lifting performance of healthy young adults in functional capacity evaluations: A comparison of two protocols

被引:8
作者
Ijmker, S
Gerrits, EHJ
Reneman, MF
机构
[1] Univ Groningen, Inst Movement Sci, Groningen, Netherlands
[2] Univ Groningen Hosp, Ctr Rehabil, Haren, Netherlands
关键词
functional capacity evaluation; lifting; validity; disability determination;
D O I
10.1023/A:1026229006792
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The objectives of this study were to explore the concurrent validity of test results of upper lifting tasks of the Ergo-Kit FCE and the Isernhagen Work Systems (IWS) FCE. Seventy-one healthy young adults performed 5 upper lifting tests with at least 5 min of rest in between. The lifting tests included 3 standard protocols and 2 modified protocols. Three criteria for concurrent validity were established: 1) Pearson correlation higher than .75, 2) nonsignificant two-tailed t test, and 3) mean difference smaller than 5 kg. The results showed that none of the criteria were met for the standard protocols. For the modified protocols criteria 2 and 3 were not met. Individual differences larger than 10 kg were found for both standard and modified protocols. It was concluded that the standard protocols for upper lifting tasks of the Ergo-Kit FCE and the IWS FCE do not meet the criteria for concurrent validity and can, therefore, not be used interchangeably.
引用
收藏
页码:297 / 305
页数:9
相关论文
共 28 条
[1]   AN ERGONOMICS APPROACH FOR THE DESIGN OF MANUAL MATERIALS-HANDLING TASKS [J].
AYOUB, MM ;
SELAN, JL ;
LILES, DH .
HUMAN FACTORS, 1983, 25 (05) :507-515
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Borg G., 1998, BORGS PERCEIVED EXER, P104
[4]   Test-retest reliability of the Isernhagen Work Systems Functional Capacity Evaluation in patients with chronic low back pain [J].
Brouwer, S ;
Reneman, MF ;
Dijkstra, PU ;
Groothoff, JW ;
Schellekens, JMH ;
Göeken, LNH .
JOURNAL OF OCCUPATIONAL REHABILITATION, 2003, 13 (04) :207-218
[5]   HAND PLACEMENT IN MANUAL MATERIALS HANDLING [J].
DRURY, CG ;
PIZATELLA, T .
HUMAN FACTORS, 1983, 25 (05) :551-562
[6]   CONCURRENT VALIDITY OF THE ERGOS WORK SIMULATOR VERSUS CONVENTIONAL FUNCTIONAL-CAPACITY EVALUATION TECHNIQUES IN A WORKERS COMPENSATION POPULATION [J].
DUSIK, LA ;
MENARD, MR ;
COOKE, C ;
FAIRBURN, SM ;
BEACH, GN .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1993, 35 (08) :759-767
[7]  
*ERG CONTR, 2000, HANDL ERG KIT
[8]   Validity of the dictionary of occupational titles residual functional capacity battery [J].
Fishbain, DA ;
Cutler, RB ;
Rosomoff, H ;
Khalil, T ;
Abdel-Moty, E ;
Steele-Rosomoff, R .
CLINICAL JOURNAL OF PAIN, 1999, 15 (02) :102-110
[9]   Reliability of safe maximum lifting determinations of a functional capacity evaluation [J].
Gross, DP ;
Battié, MC .
PHYSICAL THERAPY, 2002, 82 (04) :364-371
[10]  
Innes E, 1998, Work, V11, P207, DOI 10.3233/WOR-1998-11210